INSTALLATION
English
5. Install the two leveling studs (included with unit) into the
two threaded holes on the back of the unit.
mounting Slots on Back of Unit
6. lift the unit, and align the mounting slots on the back of the
unit with the hooks on the wall bracket. Set the unit securely
on the hooks. This step will require at least two people.
7. Check that the unit is level from front to back. adjust the
level by turning the leveling studs on the back of the unit,
if necessary.
Hanging the Unit
8. Install the mounting clips onto the back of the unit to secure
the unit to the wall bracket. There is a right clip and a left clip.
a. move the upper housing down to expose the screw on
each side of the unit that will be used to attach the
mounting clips. Remove the screws.
b. Using the correct mounting clip on each side of the unit:
i. attach the angled edge of the mounting clip to the
unit using the removed screw.
ii. attach the straight edge of the mounting clip to the
wall bracket using the screws provided.
Leveling
Studs
Mounting Slots
Upper
Housing
Upper
Housing
Existing
Screw
Bracket
Hooks
Bracket
Hooks
Right
Mounting
Clip
No surfaces
within 18″
(46 cm)
of either side.
No surfaces within 40″
(102 cm)
No surfaces
within 18″
(46 cm)
of either side.
No surfaces within 40″
(102 cm)
9. Install the drip tray and cooking grate.
10. For corded units, plug the unit into a properly grounded
electrical receptacle of the correct voltage, size, and plug
configuration. See the SPECIFICaTIONS section for details.
11. For non-corded units, have a qualified electrician install a
hardwired connection between the unit and the on-site
electrical system (refer to “Hardwired Connection” in this
section for additional information).
hardwired Connection
Hatco Salamanders can be hardwired to the electrical supply.
ELECTRIC ShOCK hAzARD:
• Units supplied without an electrical cord and plug
require a hardwired connection to on-site electrical
system. Connection must be properly grounded and of
correct voltage, size, and configuration for electrical
specifications of unit. Contact a qualified electrician to
determine and install proper electrical connection.
• Unit must be installed by a qualified electrician.
Installation must conform to all local electrical codes.
Installation by unqualified personnel will void unit
warranty and may lead to electric shock or burn, as well
as damage to unit and/or its surroundings.
• When installing a hardwired unit, a disconnect switch
must be installed between unit and main electrical
supply. The switch must be rated properly and have
contacts with a minimum opening distance of 1/8″
(3 mm).
Make sure electrical supply matches voltage and frequency
rating on specification label. Incorrect electrical supply
may damage unit.
NOTE: The specification label is located on the side of the unit
near the power inlet. See the label for verification of unit
electrical information.
1. Remove the access
panel to expose the
power inlet area of the
unit. It is located on the
right rear side of the unit
when facing the controls.
2. locate the terminal block
inside the unit.
3. Bring power leads from a
properly sized circuit
breaker or disconnect switch through the power inlet on the
unit.
4. make the appropriate connections.
• Use copper wire only.
• Tighten connections to a minimum of 40 inch pounds
(4.25 newton meters).
• a grounding screw is provided near the electrical
terminals. an equipment grounding conductor must be
properly connected to it.
5. Replace and secure the access panel.
NOTICE
Power Inlet
Access Panel
WARNING