background image

Form No. Salm-0915

13

LIMITED WARRANTy

English

1. PRODUCT WARRANTy

Hatco  warrants  the  products  that  it  manufactures  (the

“Products”)  to  be  free  from  defects  in  materials  and

workmanship, under normal use and service, for a period of

one (1) year from the date of purchase when installed and

maintained in accordance with Hatco’s written instructions or

18 months from the date of shipment from Hatco. Buyer must

establish the Product’s purchase date by registering the Product

with Hatco or by other means satisfactory to Hatco in its sole

discretion.
Hatco warrants the following Product components to be free

from defects in materials and workmanship from the date of

purchase (subject to the foregoing conditions) for the period(s)

of time and on the conditions listed below:

a) One (1) year Parts and Labor PLUS One (1) Additional

year Parts-Only Warranty:

Conveyor Toaster Elements (metal sheathed)

Drawer Warmer Elements (metal sheathed)

Drawer Warmer Drawer Rollers and Slides

Strip Heater Elements (metal sheathed)

Display Warmer Elements (metal sheathed air heating)

Holding Cabinet Elements (metal sheathed air heating)

Heated Well Elements — HW and HWB Series 

(metal sheathed)

b) One (1) year Parts and Labor PLUS Four (4) years 

Parts-Only Warranty:

3CS and FR Tanks

c) One (1) year Parts and Labor PLUS Nine (9) years 

Parts-Only Warranty on:

Electric Booster Heater Tanks

Gas Booster Heater Tanks 

d) Ninety (90) Day Parts-Only Warranty: 

Replacement Parts

THE FOREGOING WaRRaNTIES aRE EXClUSIVE aND IN

lIEU  OF  aNY  OTHER  WaRRaNTY,  EXPRESSED  OR

ImPlIED, INClUDING BUT NOT lImITED TO aNY ImPlIED

WaRRaNTY OF mERCHaNTaBIlITY OR FITNESS FOR a

PaRTICUlaR  PURPOSE  OR  PaTENT  OR  OTHER

INTEllECTUal PROPERTY RIGHT INFRINGEmENT. Without

limiting the generality of the foregoing, SUCH WaRRaNTIES

DO NOT COVER: Coated incandescent light bulbs, fluorescent

lights, heat lamp bulbs, coated halogen light bulbs, halogen heat

lamp  bulbs,  xenon  light  bulbs,  lED  light  tubes,  glass

components, and fuses; Product failure in booster tank, fin tube

heat exchanger, or other water heating equipment caused by

liming,  sediment  buildup,  chemical  attack,  or  freezing;  or

Product  misuse,  tampering  or  misapplication,  improper

installation, or application of improper voltage.

2. LIMITATION OF REMEDIES AND DAMAGES

Hatco’s liability and Buyer’s exclusive remedy hereunder will be

limited solely, at Hatco’s option, to repair or replacement using

new  or  refurbished  parts  or  Product  by  Hatco  or  a  Hatco-

authorized service agency (other than where Buyer is located

outside  of  the  United  States,  Canada,  United  Kingdom,  or

australia, in which case Hatco’s liability and Buyer’s exclusive

remedy hereunder will be limited solely to replacement of part

under  warranty)  with  respect  to  any  claim  made  within  the

applicable warranty period referred to above. Hatco reserves

the right to accept or reject any such claim in whole or in part.

In the context of this limited Warranty, “refurbished” means a

part  or  Product  that  has  been  returned  to  its  original

specifications by Hatco or a Hatco-authorized service agency.

Hatco will not accept the return of any Product without prior

written approval from Hatco, and all such approved returns shall

be  made  at  Buyer’s  sole  expense.  HaTCO  WIll  NOT  BE

lIaBlE, 

UNDER  aNY 

CIRCUmSTaNCES, 

FOR

CONSEQUENTIal OR INCIDENTal DamaGES, INClUDING

BUT NOT lImITED TO laBOR COSTS OR lOST PROFITS

RESUlTING FROm THE USE OF OR INaBIlITY TO USE THE

PRODUCTS  OR  FROm  THE  PRODUCTS  BEING

INCORPORaTED  IN  OR  BECOmING a  COmPONENT  OF

aNY OTHER PRODUCT OR GOODS.

Summary of Contents for SAL Series

Page 1: ...er falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesión o muerte Este manual contiene importante información sobre seguridad concerniente al mantenimiento uso y operación de este producto Si usted no puede entender el contenido de este manual por favor pregunte a su supervisor Almacenar este manual en una localización segura para la referencia fu...

Page 2: ... Information 2 Introduction 2 Important Safety Information 3 Model Description 4 Model Designation 4 Specifications 4 Plug Configuration 4 Electrical Rating Chart 5 Dimensions 5 Installation 6 General 6 Installing a Wall mounted Unit 7 Hardwired Connection 8 Operation 9 General 9 Control Panel 9 Operating the Salamander 10 Maintenance 11 General 11 Daily Cleaning 11 Troubleshooting Guide 12 Limite...

Page 3: ...CK hAzARD Plug unit into a properly grounded electrical receptacle of the correct voltage size and plug configuration If plug and receptacle do not match contact a qualified electrician to determine and install the proper voltage and size electrical receptacle Units supplied without an electrical cord and plug require a hardwired connection to on site electrical system Connection must be properly ...

Page 4: ...rical requirements before beginning installation Do not install unit above grills fryers or other appliances that will expose unit to high temperature excessive moisture or grease laden air Improper installation will void warranty Use non abrasive cleaners and cloths only Abrasive cleaners and cloths could scratch finish of unit marring its appearance and making it susceptible to soil accumulation...

Page 5: ...kg 230 4133 17 2 1 50 60 Hardwired 113 lbs 52 kg 144 lbs 65 kg 230 400Y 4133 5 7 3 50 60 Hardwired 113 lbs 52 kg 144 lbs 65 kg Model Width A Depth B height C Footprint Width D Footprint Depth E Cooking Width F Cooking Depth G Cooking height h Sal 1 22 11 16 576 mm 22 11 16 576 mm 23 13 16 603 mm 20 1 2 520 mm 17 1 2 443 mm 21 7 8 556 mm 13 3 4 350 mm 4 to 8 1 2 102 to 216 mm Form No Salm 0915 5 SP...

Page 6: ...unit or its contents from falling accidentally and strong enough to support the weight of the unit and contents Do not place anything on top of unit doing so may subject personnel to injury or damage unit NOTE A qualified person must check possible placements of the salamander to ensure that the proper electrical supply line is available 1 Remove the unit from the shipping carton NOTE To prevent d...

Page 7: ...ke sure the unit is at the proper height in an area convenient for use Wall Countertop 2 51 mm 18 46 cm 18 46 cm 12 30 cm Non Combustible Construction Top View Parts Included The following parts are included with wall mounted units Item Quantity Wall Bracket 1 mounting Clip 2 1 4 x 2 1 2 6 x 64 mm lag Screw 4 Hex Screw 4 Installation Procedure Use the following procedure to install a wall mounted ...

Page 8: ...ed Connection in this section for additional information hardwired Connection Hatco Salamanders can be hardwired to the electrical supply ELECTRIC ShOCK hAzARD Units supplied without an electrical cord and plug require a hardwired connection to on site electrical system Connection must be properly grounded and of correct voltage size and configuration for electrical specifications of unit Contact ...

Page 9: ... SET slider key increases the timer setting or selects a higher temperature setting Sliding a finger from the top to the bottom of the SET slider key decreases the timer setting or selects a lower temperature setting Display The display shows the timer settings or temperature settings depending on the function selected by the COOK HOlD key When a COOK or HOlD cycle is activated by the STaRT STOP k...

Page 10: ...etection feature and the unit will automatically activate the programmed timer setting The STaRT indicator light will illuminate to indicate the COOK cycle is in progress an audible beep will sound and the plate detection indicator will darken in the display 20 00 STARTED 10 23 Plate Detection Indicator Using the Plate Detection Bar NOTE The operator can adjust the timer setting and turn the heati...

Page 11: ...n off the STOP indicator light will illuminate and three audible beeps will sound b Remove the food plate from the cooking grate releasing the plate detection bar The element s will turn off the STOP indicator light will illuminate three audible beeps will sound and the plate detection indicator in the display will go out 9 To continue to hold other foods touch the STaRT STOP key to reset the unit...

Page 12: ...p contact an authorized Hatco Service agent or Hatco for assistance Timer or Heat mode switch defective Contact an authorized Hatco Service agent or Hatco for assistance Form No Salm 0915 12 TROUBLEShOOTING GUIDE English This unit must be serviced by trained and qualified personnel only Service by unqualified personnel may lead to electric shock or burn WARNING ELECTRIC ShOCK hAzARD Turn OFF power...

Page 13: ... INTEllECTUal PROPERTY RIGHT INFRINGEmENT Without limiting the generality of the foregoing SUCH WaRRaNTIES DO NOT COVER Coated incandescent light bulbs fluorescent lights heat lamp bulbs coated halogen light bulbs halogen heat lamp bulbs xenon light bulbs lED light tubes glass components and fuses Product failure in booster tank fin tube heat exchanger or other water heating equipment caused by li...

Page 14: ...il Informations Importantes pour le Propriétaire 14 Introduction 14 Consignes de Sécurité Importantes 15 Description du Modèle 16 Désignation du Modèle 16 Caractéristiques Techniques 17 Configuration des fiches 17 Tableau des valeurs nominales électriques 17 Dimensions 17 Installation 18 Généralités 18 Installation d un appareil qui se fixe sur un mur 19 Branchement des câbles 21 Mode d emploi 22 ...

Page 15: ...se de courant avec terre de tension de format et de configuration des broches corrects Si la fiche et la prise ne se correspondent pas s adresser à un électricien qualifié pour déterminer et installer une prise de courant de format et de tension corrects Les appareils fournis sans cordon ni prise électrique nécessitent un branchement câblé au système électrique sur place Le câblage doit être mis à...

Page 16: ...MANUAL FOR MORE INFORMAT ION Panneau de commande Cuvette d égouttage Barre de détection des plaques Grille de cuisson Partie supérieure DéSIGNATION DU MODèLE DESCRIPTION DU MODèLE S A L 1 Salamander Capacité quantité de récipients de cuisson de grande capacité Aucun élément ne doit être posé sur l unité Le non respect de cette consigne pourrait causer des dommages sur le personnel et l équipement ...

Page 17: ...rancher l appareil sur une prise de courant avec terre de tension de format et de configuration des broches corrects Si la fiche et la prise ne se correspondent pas s adresser à un électricien qualifié pour déterminer et installer une prise de courant de format et de tension corrects Les appareils fournis sans cordon ni prise électrique nécessitent un branchement câblé au système électrique sur pl...

Page 18: ...ation ou combustion peut avoir lieu Veillez à ne pas obstruer les orifices d entrée ou de sortie d air situés sur la partie externe de l unité Cela pourrait provoquer une combustion ou une défaillance de l unité En cas de montage mural utilisez exclusivement le support mural fourni avec l unité Fixez ce support à une surface solide et non combustible à l aide d un matériel adapté à la surface de m...

Page 19: ... et possédant la tension la dimension et la configuration adéquates Consultez la section CaRaCTÉRISTIQUES pour obtenir plus de détails 11 Pour les appareils non câblés demandez à un électricien qualifié d installer un branchement câblé entre l appareil et le système électrique sur place veuillez vous référer à Branchement des câbles dans cette section pour obtenir des informations supplémentaires ...

Page 20: ...deux goujons de mise à niveau inclus avec l appareil dans les deux orifices filetés à l arrière de l appareil Revêtement d 13 mm 1 2 Support mural Trous de guidage de 5 mm 3 16 Vis tire fond Ossature en bois 2x4 avec 406 mm 16 au centre Ossature en bois 2x4 avec 406 mm 16 au centre Fentes de fixation situées à l arrière de l unité 6 Soulevez l appareil et alignez les fentes de fixation à l arrière...

Page 21: ...tie de l appareil Cela peut également entraîner un choc électrique ou une brûlure et endommager l unité et ou les zones environnantes Lors de l installation d un appareil câblé un sectionneur doit être installé entre l appareil et l alimentation électrique principale La puissance du sectionneur doit être adaptée et il doit disposer de contacts dotés d une distance d ouverture minimale de 3 mm 1 8 ...

Page 22: ...eur sert à sélectionner la température de conservation souhaitée parmi les huit 8 niveaux de température préréglés le curseur SET RÉGlaGE peut être utilisé de deux façons en appuyant dessus ou en le faisant glisser En appuyant dessus En appuyant sur la flèche dirigée vers le haut vous augmentez le réglage du minuteur ou choisissez un réglage de température plus élevé En appuyant sur la flèche diri...

Page 23: ...mmencer le décompte du minuteur programmé le voyant indicateur de DÉmaRRaGE s allume et vous entendez un bip sonore qui signale la mise en route du cycle de CUISSON l affichage indique le temps restant du cycle 20 00 b appuyez à l aide de la plaque d aliments sur la barre de détection des plaques Cette action enclenche la fonctionnalité de détection des plaques et l appareil active automatiquement...

Page 24: ...nnalité de détection des plaques et l appareil met automatiquement sous tension les éléments sélectionnés au niveau de température préprogrammé le voyant indicateur de DÉmaRRaGE s allume pour signaler la mise en route du cycle de CONSERVaTION vous entendez un bip sonore et l indicateur de détection des plaques s assombrit dans l affichage l appareil reste en marche jusqu à ce que vous appuyiez sur...

Page 25: ... l aide d un chiffon imprégné d eau chaude 5 Séchez l unité à l aide d un chiffon sec propre et non abrasif AVIS Généralités l appareil Salamander Hatco est conçu pour assurer une durabilité et une efficacité maximales tout en réduisant la fréquence des opérations de maintenance DANGER DE DéChARGE éLECTRIQUE Mettez l interrupteur sur ARRÊT débranchez le cordon d alimentation coupez le courant au d...

Page 26: ...coupe circuit a disjoncté Redémarrez le coupe circuit Si le coupe circuit continue de disjoncter contactez un agent de service agréé ou Hatco pour obtenir une assistance Panneau de commande électronique défaillant Contactez votre agent de maintenance agréé ou Hatco pour toute demande d assistance La réparation de cet appareil doit être confiée exclusivement à du personnel qualifié Les réparations ...

Page 27: ...PROPRIÉTÉ INTEllECTUEllE Sans restreindre la portée générale des énoncés précédents CES GaRaNTIES NE COUVRENT PaS ampoules d éclairage à incandescence enduites lumières fluorescentes ampoules de lampes chauffantes ampoules d éclairage à halogène enduites ampoules de lampes chauffantes au xénon tubes d éclairage DEl composants en verre et fusibles défaut de produit dans la cuve d un appareil de cha...

Page 28: ...314 890 0700 Kaemmerlen Parts Service St louis 314 535 2222 NEBRASKA anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial las Vegas 702 736 0006 Hi Tech Commercial Service N las Vegas 702 649 4616 NEW JERSEy Jay Hill Repair Fairfield 973 575 9145 Service Plus Flanders 973 691 6300 NEW yORK acme american Repairs Inc Brooklyn 718 456 6544 alpro Service Co Brooklyn 718 386 2515 appliance I...

Reviews: