Settings for the pulsating flow Setup menu:
Fct. code Function name
Suggested settings
Description
Call up through the function matrix:
B
QUICK SETUP
QUICK SETUP PULS. FLOW
1003
QUICK SETUP PULSATING FLOW
YES
Basic configuration:
2002
DISPLAY DAMPING
1 s
6606
SPECIAL FILTER
DYNAMIC FLOW
3002
TOTALIZER MODE (DAA)
BALANCE
3002
TOTALIZER MODE (DAB)
BALANCE
3002
TOTALIZER MODE (DAC)
BALANCE
Select the signal type: CURRENT OUTPUT (1 to 2)
4004
MEASURING MODE
PULSATING FLOW
4005
TIME CONSTANT
1 s
Select the signal type: FREQ./PULSE OUTPUT (1 to n) / operating mode: FREQUENCY
4206
MEASURING MODE
PULSATING FLOW
4208
TIME CONSTANT
0 s
Select the signal type: FREQ./PULSE OUTPUT (1 to n) / operating mode: PULSE
4225
MEASURING MODE
PULSATING FLOW
Other settings:
8005
ALARM DELAY
0 s
6400
ASSIGN LOW FLOW CUT OFF
VOLUME FLOW
6402
ON-VALUE LOW FLOW CUT OFF
see table below
6403
OFF-VALUE LOW FLOW CUT OFF
50%
6404
PRESSURE SHOCK SUPPRESSION
0 s
Recommended settings for the function ASSIGN LOW FLOW CUT OFF (6400):
DN
[mm] [inch]
dm
3
/min
US-gal/min
2
1/12"
0.002
0.001
4
5/32"
0.007
0.002
8
5/16"
0.03
0.008
15
½"
0.1
0.03
25
1"
0.3
0.08
32
1 ¼"
0.5
0.15
40
1 ½"
0.7
0.2
50
2"
1.1
0.3
65
2 ½"
2.0
0.5
80
3"
3.0
0.8
100
4"
4.7
1.3
The recommended values correspond to the max. full scale value per DN divided by 1000
(see Operating Instructions Promag 55, BA119D/06, Chapter "Installation"
→
nominal
diameters and flow rates).
Summary of Contents for Proline Promag 55
Page 2: ...Device Functions Proline Promag 55 2 Endress Hauser ...
Page 5: ...Device Functions Proline Promag 55 Contents Endress Hauser 5 ...
Page 164: ...14 Index Device Functions Proline Promag 55 164 Endress Hauser ...
Page 166: ...www endress com worldwide BA120D 06 en 10 09 71104957 FM SGML6 0 ...