9 Block BASIC FUNCTION
Hauser
119
EPD RESPONSE TIME
(6425)
!
Note!
The function is only available if the function EMPTY PIPE DETECTION (6420) has been
switched on.
Use this function to enter the time span for which the criteria for an "empty" pipe have to
be satisfied without interruption before a notice message or fault message is generated.
User input:
Fixed-point number: 1.0 to 100 s
Factory setting:
1.0 s