FAX 5/10/20/30/40KW
October 28, 2013
2
‐
13
888
‐
2720
‐
001
WARNING:
Disconnect
primary
power
prior
to
servicing.
Copyright
©2013,
Harris
Broadcast
2.10.2
AC Connection with Distribution Panel
When
the
FAX
is
installed
in
a
Harris
Broadcast
cabinet
with
the
AC
Distribution
Panel
option
installed,
there
is
only
one
AC
service
connection
required.
Figure
2
‐
9
shows
the
AC
Distribution
panel
which
provides
a
breaker
to
each
power
block
in
the
transmitter
as
well
as
an
outlet
strip
for
the
exciter
and
peripheral
equipment.
However
there
will
need
to
be
a
properly
sized
breaker
external
to
the
transmitter
that
is
customer
provided.
If
this
has
not
been
installed
please
refer
to
Section
1
of
this
manual
to
determine
the
correct
breaker
and
wire
size
for
your
model.
However,
ensure
all
local
electrical
codes
are
followed.
Figure 2-9 AC Input Terminal Block (3-Phase Delta Shown)
Review
the
following
checklist
before
continuing.
•
Confirm
presence
of
safety
ground
wire
connection
as
shown
in
Figure
2
‐
9.
•
The
AC
Mains
wires
for
Line
and
Neutral(Neutral
used
on
Wye
only
at
330
‐
460
VAC
range)
are
in
correct
loca
‐
tion
and
tight.
•
Be
sure
all
AC
covers
are
replaced.
Note
If using a 3-Phase Wye service in the range of 190-264 VAC the transmitter will be strapped internally for
delta. The AC Distribution panel will not have a Neutral bar. If the Neutral Bar is required to meet the
electrical code in your area please contact Harris Broadcast Service to obtain a terminal barrier strip
Qty-1 part number 614-0988-000.
2.11
Cooling Installation
Now
that
the
AC
and
the
RF
line
has
been
installed
any
cooling
duct
work
can
be
installed.
See
Section
1
of
the
manual
for
detailed
guidelines
on
installing
a
closed
‐
loop
or
open
‐
loop
cooling
system.
2.12
Initial Turn On
At
this
point
in
the
installation
the
following
items
should
be
completed.
If
not
then
please
go
back
to
the
related
section
and
complete
the
task
before
continuing
with
turning
on
the
transmitter.
•
AC
Mains
and
safety
ground
should
be
connected
and
all
safety
covers
replaced
•
Transmitter
cabinet
should
be
grounded
to
the
building
ground
using
at
least
2"
copper
strap