3.9.6
SETUP>TX CALIBRATE>POWER SUPPLY SET
There
is
a
power
supply
setpoint
stored
for
each
of
the
Modulation
modes,
FM,FM+HD
and
HD.
If
the
transmitter
is
setup
to
run
in
more
than
one
mode
the
supply
voltage
must
be
set
for
each
mode
that
will
be
used.
All
supplies
in
all
of
the
power
blocks
will
be
set
to
this
voltage.
Warning
THE TRANSMITTER RUNS MOST EFFICIENT AT LOWER SUPPLY VOLTAGES, HOWEVER
THE TRANSMITTER CAN FAULT UNDER CERTAIN CONDITIONS (FREQUENCY, QUALITY
OF LOAD, ETC) WHEN THE POWER SUPPLY VOLTAGE IS SET TOO LOW. TYPICAL
FAULTS WILL BE PA MODULE OVERDRIVE. IF THE TRANSMITTER IS REPORTING THIS
FAULT AND POWER SUPPLY VOLTAGE IS SET TO MINIMUM, TRY RAISING THE VOLT-
AGE UP 2 VOLTS TO SEE IF THE PROBLEM CLEARS.
3.9.7
SETUP>TX CALIBRATE>AIRFLOW SET
To
set
airflow
the
transmitter
fans
must
be
at
full
speed
which
is
100%
airflow.
Also
prior
to
calibrating
airflow
the
air
filters
should
be
checked
and
cleaned
if
necessary.
See
Section
5
of
this
manual
for
airflow
calibration
procedure.
Airflow
calibration
must
be
completed
for
power
block
in
the
transmitter.
Table 3-10 SETUP>TX CALIBRATE>TX POWER CAL
Menu
Description
MODULATION
Transmitter
mode
to
calibrate
power
in;FM,FM+HD,HD;
Set
by
exciter
TX
TPO
RF
Power
to
calibrate
the
transmitter
at
(TPO)
CALIBRATE
Calibrate
YES
or
NO
Table 3-11 SETUP>TX CALIBRATE>POWER SUPPLY SET
Menu
Description
MODULATION
Transmitter
mode
to
set
power
supply
voltage;FM,FM+HD,HD
Should
match
exciter
mode.
PS
SET
Voltage
to
set
the
power
supply
DC
output
between
44
and
52
VDC
in
0.1
Volt
steps
SET
YES
or
NO