background image

2

TL2.0 Woodburning Stove

Dry Seasoned Wood Only!

Save These Instructions

Harman®  •  TL2.0 Owner's Manual_R20  •  2011 -___  •  09/15

May be burned as a fireplace with “Cozy Screen” Part# 3-40-06960 in place over door opening. Otherwise, doors must remain closed during operation

Peux fonctionner comme un foyer avec la pièce no. 3-40-06960 ‘’ Cozy Screen ‘’ placée au dessus  de l’ouverture de la porte. Autrement , les portes doivent demeurer fermées durant  le fonctionnement.

US ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with 2015 particulate emission standards. Not approved for sale after May 15, 2020.

Certifié conforme aux normes 2015 d’émission de particules. Non approuvé pour la vente après le 15 mai 2020.

REFER TO PRODUCT MANUAL FOR CLEARANCES WITH ADDITIONAL VENT CONFIGURATIONS.

Veuillez vous référer au manuel d’instruction pour informations additionnels pour la configuration de 

la ventilation.

Floor protection must be a non-combustible material. Must also be 

placed under any horizontal sections of flue connector, extending 

2” (51mm) beyond each side of the connector. / Pour protéger le 

plancher, il faut sous le poêle un matériau. Qui doit aussi être placé 

sous les parties horizontales du tuyau de raccord à la cheminée et 

s’étendre à 51 mm (2 po) au-delà de lateral du tuyau.

When  installed  with  the  optional  leg  kit,  The  bottom  heat  shield 

must be in place, and the area under the appliance kept clear. Que 

installé avec le kit de jambe optionnel, le bouclier de chaleur de 

fond doit être dans l’endroit et la région sous l’appareil gardé clair.

Rev E

P.N. 3-90-00856

352 Mountain House Road

Halifax, PA 17032

ECO: 
PARt # / REv:  3-90-00856_RevE
ORiginAtOR:  Spidle
DAtE:  04/15
LAbEL SizE:  11.5 in. x 6.5 in.
LOCAtiOn: 

Rear of Stove

CLASS: 
ADHESivE: 

468

MAtERiAL: 

MEtAL

ink: bLACk
OvERCOAt:

LAbEL tiCkEt

(4) Hole Size = .187

Corners .062

MODEL / MODÈLE: “TL2.0” Woodburning Stove

Room Heater Solid Fuel Burning Type

SUITABLE FOR MOBILE-HOME INSTALLATION

 

(USA ONLY)

Report #/ Raport #

135-S-29-2

Tested to / Testé à:

 UL 1482-2011, UL 737-2011, ULC-S627-00, EPA Method 28 & 5G

Approved For Use in Mobile/Manufactured Homes (UM) 84-HUD - 

USA ONLY

“PREVENT HOUSE FIRES” 

Install and use only in accordance with manufacturer’s installation 

and operation instructions and local  codes.  In absence  of local  codes,  installation  must meet 

minimum requirements of NFPA 211 in USA. Refer to manufacturer’s instructions and local codes 

for precautions required for passing chimney through a combustible wall or ceiling.

This wood heater needs periodic inspection and repair for proper operation. Consult the owner’s 

manual for further information. It is against federal regulations to operate this wood heater in a 

manner inconsistent with the operating instructions in the owner’s manual.

WARNING: FOR MANUFACTURED HOMES:

 (US Only) Do not install appliance in a sleeping 

room. An outside air inlet must be provided. The structural integrity of the manufactured home’s 

floor, walls, and ceiling must be maintained.

Flue connector pipe must be 6” diameter, minimum 24 MSG blue steel. Chimney must be factory 

built 103HT or masonry construction. Contact Local Building or Fire Officials about restrictions and 

installation inspection in your area.

DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY SERVING ANOTHER APPLIANCE.

FOR USE WITH SOLID WOOD FUEL ONLY, DO NOT bURN COAL.

EPA Certified Emissions: 2.6 g/hr

Fuel Type: Cord Wood

DO NOT Overfire - If Heater or chimney connector glows, you are overfiring.

Optional Blower Harman #1-00-856002: Electrical Rating 115 VAC, 60Hz, 1AMP Maximum 

Route power cord away from unit.

OPERATE ONLY wITh dOORS CLOSEd

 

Replace glass only with 5mm ceramic, available from your dealer.

Combustible flooring must be protected with an approved 0.45R hearth board.

Appliance must be installed with the legs attached. Do not obstruct airflow under the appliance.

DANGER: Risk of Fire or Explosion - Do not burn garbage,  gasoline, drain oil or other 

flammable liquids.

WARNING: Risk of Fire, Do not operate with fuel loading or ash removal doors open.

Do not store fuel or combustibles within marked clearances. Inspect and clean chimney 

and connector regularly - Under certain conditions of use, creosote buildup may occur 

rapidly.

The bypass Damper must be opened prior to opening any load or ash door.

Do not install a grate or otherwise elevate the fire.

DO NOT REMOVE THIS LAbEL / Ne pas enlever cette étiquette

Date of Manufacture / Date de fabrication:

2015   2016   2017   JAN   FEB   MAR   APR   MAY   JUN   JUL   AUG   SEP   OCT   NOV   DEC

Manufactured by / Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032

A

 = Unit to Sidewall 

 

14”

b

 = Unit to Backwall 

 

13”

C

 = Chimney Connector to Sidewall 

24”

d

 = Chimney Connector to Backwall 

18”

E

 = Unit to Adjacent Wall   

16”

F

 = Chimney Connector to Adjacent Wall  22-1/2”

CLEARANCE TO COMbUSTIbLE SURFACES

A

 = Entre le mur lateral et l’appareil 

356mm

b

 = Entre le mur arriereet l’appareil 

330mm

C

 = Entre le tuyau et le mur lateral 

610mm

d

 = Entre le tuyau et le mur arriere 

457mm

E

 = Entre le mur adjacent et l’appareil 

406mm

F

 = Entre le tuyau et le mur adjacent 

571mm

CLEARANCE TO COMbUSTIbLE SURFACES

Maisons approuvé pour utilisation à Mobile / manufacturés (UM) 84-HUD - 

USA SEULEMENT

"Empêcher  MAISON  incendies"

  Installer  et  utiliser  uniquement  en  conformité  avec  installation  et 

d'utilisation les instructions du fabricant et les codes locaux. En l'absence de codes locaux, l'installation doit 

satisfaire aux exigences minimales de la norme NFPA 211 aux Etats-Unis. Reportez-vous aux instructions 

du fabricant et les codes locaux pour les précautions nécessaires pour faire passer la cheminée à travers 

un mur ou un plafond combustible.

Ce poêle à bois doit inspection périodique et la réparation pour un fonctionnement correct. Consultez le 

manuel du propriétaire pour plus d'informations. Ce est contre les règlements fédéraux pour faire fonctionner 

ce poêle à bois d'une manière incompatible avec les instructions d'utilisation dans le manuel du propriétaire.

AVERTISSEMENT: POUR maisons préfabriquées:

 (États-Unis uniquement) Ne pas installer l'appareil 

dans une chambre à coucher. Une entrée d'air extérieur doit être fournie. L'intégrité structurale du sol, les 

murs et le plafond de la maison préfabriquée doit être maintenue.

Tuyau  de  raccordement  de  fumée  doit  être  de  6  "de  diamètre,  en  acier  au  minimum  24  MSG  bleu. 

Cheminée doit être construite l'usine 103HT ou la construction de maçonnerie. Contactez Immeuble Local 

ou fonctionnaires incendie au sujet des restrictions et l'inspection d'installation dans votre région.

NE PAS brancher l'appareil à une cheminée desservant un autre APPAREIL.

Pour une utilisation avec Solid combustible bois Seulement, Ne pas brûler de charbon.

Émissions certifiés EPA: 2,63 g / h

Type de carburant: Cordon bois

NE SURCHAUFFEZ - Si le connecteur chauffe ou de la cheminée rougeoie, vous surchauffez.

Facultatif Blower Harman # 1-00-856002: Note électrique 115 VAC, 60Hz, 1AMP maximum

Route cordon électrique de l'appareil.

FONCTIONNER UNIQUEMENT AVEC LES PORTES FERMéES

Remplacer le verre seulement avec de la céramique 5mm, disponible chez votre revendeur.

Plancher combustible doit être protégé par un conseil 0.45R foyer approuvé.

L'appareil doit être installé avec les jambes attachées. Ne pas obstruer le flux d'air sous l'appareil.

DANGER: risque d'incendie ou d'explosion - Ne pas brûler de déchets, de l'essence, vidanger l'huile 

ou d'autres liquides inflammables.

AVERTISSEMENT:  Risque  d'incendie,  ne  pas  fonctionner  avec  chargement  de  combustible  ou 

d'enlèvement de cendres portes ouvertes.

Ne  pas  stocker  carburants  ou  de  combustibles  dans  les  dégagements  marqués.  Inspectez 

et  cheminée  propre  et  le  connecteur  régulièrement  -  Dans  certaines  conditions  d'utilisation, 

l'accumulation de créosote peut se produire rapidement.

Le bypass amortisseur doit être ouvert avant d'ouvrir ne importe quelle porte de charge ou de la 

cendre.

Ne pas installer une grille ou autrement surélever le feu.

d

b

C

A

E

F

Made  in  U.S.A.  of  US  and  imported  parts.  /  Fabriqué  aux  états-Unis-

d’Amérique par des pièces d’origine américaine et pièces importées.

USA

8”

8” (200mm)

CAN 

200mm

18”

457mm

ATTENTION:

CHAUD LORS DU FONCTIONNEMENT- NE TOUCHEZ PAS 

L’APPAREIL-GARDEZ LES ENFANTS ET LES VÊTEMENTS ÉLOIGNÉS- TOUT CONTACT 

PEUT ENTRAÎNER DES BRÛLURES DE LA PEAU. RÉFÉREZ-VOUS À LA PLAQUE 

SIGNALÉTIQUE ET AU MODE D’EMPLOI. GARDEZ LE MOBILIER ET LES AUTRES 

MATÉRIAUX COMBUSTIBLES BIEN À L’ÉCART DE L’APPAREIL.

CAUTION:

HOT wHILE  IN  OPERATION-  DO  NOT  TOUCH- 

kEEP CHILDRENAND CLOTHING AwAY- CONTACT MAY CAUSE SkIN 

BURNS- SEE NAMEPLATE AND INSTRUCTIONS. kEEP FURNISHINGS 

AND OTHER COMBUSTIBLE MATERIALS A CONSIDERABLE DISTANCE 

AwAY FROM THE APPLIANCE

BARCODE LABEL

008

Serial No.

N

o

 de série:

Hearth & Home Technologies welcomes you to our tradition of excellence! By choosing a Harman appliance, you have become 

part of our commitment to meeting the heating needs of consumers with the most distinctive, powerful and responsible home 

heating products available. 
With it's compact, steel-body construction, the TL2.0 takes advantage of Harman’s 30+ years of stove design, technology and 

manufacturing. The Firedome Plus secondary combustion system provides for super-clean burning and minimal maintenance. 

The top-loading feature makes for more convenient loading, with enough fuel for an all day burn.
We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance.
Thank you for choosing Harman.

This Label is located on the rear of the appliance. It contains important safety test information as well as the clearances to 

combustible materials. The label also contains the appliance serial number. For your records, copy your serial number and 

purchase date here.

Serial #: ________________________    

Date of Purchase: ________________________

SAMPLE LABEL

Summary of Contents for TL2.0

Page 1: ...ay CAREFULLY SUPERVISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing fur...

Page 2: ...E SURFACES A Entre le mur lateral et l appareil 356mm b Entre le mur arriereet l appareil 330mm C Entre le tuyau et le mur lateral 610mm d Entre le tuyau et le mur arriere 457mm E Entre le mur adjacen...

Page 3: ...Use Checklist 8 Section 4 Dimensions Clearances A Appliance Dimensions 9 B Clearances to Combustibles 10 C Floor Protection 12 Section 5 Chimneys Venting A Draft 13 B Chimney Connectors 13 C Wall Pass...

Page 4: ...ertified to comply with 2015 particulate emission standards Not approved for sale after May 15 2020 MODEL TL2 0 Woodburning Stove LABORATORY OMNI Test Laboratories Inc REPORT NO 135 S 29 2 TYPE Solid...

Page 5: ...crease ventilation by opening windows or doors 2 Make sure the stove doors and lid are closed and latched 3 Check stove for smoking or puffing condition Open by pass and increase air flow to firebox i...

Page 6: ...ration must be given to safety convenience traffic flow and the fact that the appliance will need a chimney and chimney connector It is a good idea to plan your installation on paper using exact measu...

Page 7: ...nstructions Harman TL2 0 Owner s Manual_R20 2011 ___ 09 15 C Component Locations Top Load Opening Air Control Front Load Door Top Load Door Bypass Damper Control Handle Ash Door Ash Door Latch Front L...

Page 8: ...1 Place the appliance in a location near the final installation and follow the procedures below 2 Open the appliance and remove all articles packed inside Inspect all items for shipping damage Notify...

Page 9: ...oodburning Stove Save These Instructions Harman TL2 0 Owner s Manual_R20 2011 ___ 09 15 A Appliance Dimensions 25 7 8 657mm 26 7 8 665mm 32 5 16 820mm 35 5 16 897mm Air Intake 9 1 8 231mm 4 Dimensions...

Page 10: ...C Vent Pipe to Side Wall 24 640mm 24 610mm D Vent Pipe to Back Wall 18 457mm 12 305mm Corner Installation E Corner to Adjacent Wall 16 406mm 10 254mm F Connector to Wall 22 1 2 457mm 16 1 2 419mm For...

Page 11: ...ipe to Side Wall 23 584mm D Vent Pipe to Back Wall 18 457mm E Vent Pipe to Ceiling 16 406mm Corner Installation F Corner to Adjacent Wall 16 406mm G Connector to Wall 22 1 2 571mm For clearance reduct...

Page 12: ...on dimensions for the front and sides are measured from the appliance door opening in The United States In Canada the side dimension is measured from the widest part of the appliance Parallel versus C...

Page 13: ...pond to the size of the flue collar opening which is 6 152mm Do not use makeshift compromises No part of the chimney connector may pass through an attic or roof space closet or other concealed space o...

Page 14: ...m above the highest point at which they exit from the roof Then the chimney must extend 2 ft 0 6m above the highest point within a 10ft 3m radius Thus the 3 foot 2 foot 10 foot rule 3ft Above roof exi...

Page 15: ...Protection in this section Since many fireplaces have exposed wooden mantels and trim pay special attention to the clearances necessary to these materials If your fireplace chimney is behind a combus...

Page 16: ...ough an Attic or Roof Space Closet or Similar Concealed Space a Floor or Ceiling Chimney Connector Minimum air space with chimney listing Chimney support Attic radiation shield Chimney sections Chimne...

Page 17: ...ns Harman TL2 0 Owner s Manual_R20 2011 ___ 09 15 Chimney Connector Cathedral style chimney support Finishing collar Roof radiation shield Chimney cap Sealed storm collar Roof flashing Factory Built m...

Page 18: ...ce Closet or Similar Concealed Space a Floor or Ceiling Minimum clearance to unprotected ceiling 15 Chimney connector sealed at thimble Flue liner with required air space Minimum of three sheet metal...

Page 19: ...led Space a Floor or Ceiling Minimum clearance from chimney connector to uprotected ceiling 15 Flue liner with required air space Listed or approved thimble assembly 1 Clearance for exterior chimney o...

Page 20: ...cone to create an effective vapor barrier at the location where the chimney or other component penetrates to the exterior 8 Installation shall be in accordance with the Manufactured Home and Safety St...

Page 21: ...de the other end of the metal intake flex pipe into the stub on the rear of the stove and secure it with aluminum tape This air intake will supply outside air for the secondary combustion 7 Secure the...

Page 22: ...is best to remove the door by lifting from the hinges Lay the door down flat on it s face Drill the dimpled holes in each corner of the door and re install the door onto the stove From the outside in...

Page 23: ...he door push the door closed with the handle in the open position then turn counter clockwise to engage the latch Ash Door To open the ash door lift up the handle and pull out Close the door by pushin...

Page 24: ...ntent in the wood fuel Ash remains after the burning is complete Within the primary firebox two or more of these stages of combustion are occurring at once Always be sure to provide adequate ventilati...

Page 25: ...g door s Allow this start up fire to burn for a few minutes keeping the bypass damper open Add about five more pieces of wood in the 2 to 3 inch 50 80mm size range making sure that the fuel bed is all...

Page 26: ...e ashes from the fire chamber periodically by raking a poker across the bottom grates Excessive ash buildup can prevent proper venting of exhaust gases Do not allow the ash pan to over fill Ash buildu...

Page 27: ...aters must be cleaned regularly as soot ash and creosote may accumulate ALWAYS WEAR FIRE RESISTANT GLOVES TO OPERATE THE STOVE THE AIR CONTROL IS HOT WHILE IN OPERATION CAUTION When properly maintaine...

Page 28: ...posed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have completely cooled Other waste shall not be placed in this container Gla...

Page 29: ...ousing Alternately with some minor disassembly you can use a vacuum and or brush to clean the blower wheel Reinstall the blower and tighten the four bolts securely Chimney Connector Frequency As neces...

Page 30: ...se Instructions Harman TL2 0 Owner s Manual_R20 2011 ___ 09 15 Variable Speed Switch Power Cord Blower Thermostat Grounded to housing Black Wire White Wire 2 1 TL2 0 TL2 6 Optional Blower Kit 1 00 856...

Page 31: ...08560 Service Parts TL2 0 Beginning Manufacturing Date Sept 2011 Ending Manufacturing Date Active Part number list on following page Wood Stove 1 90 856000 1 Black W Pedestal 08 15 2 3 1 4 6 7 8 9 10...

Page 32: ...49145 Y Gasket 1 Single Ply Tape 10 Ft 1 00 88100 Y 3 Firedome Plus Combustion Package w Gaskets 3 40 358110 Y Gasket brick air Pkg of 4 3 44 2500202 4 Y Gasket Set Complete 3 44 358110 Y 4 Rear brick...

Page 33: ...1 00 856008 Y 19 Air control weldment 1 10 856004W Y 20 Air slide 1 10 856003W Y 21 Ash pan 1 10 856006A Y 22 Combustion shoe brick 3 40 00100 Y Shoe brick gasket 3 44 06951 Y 23 Side brick insulatio...

Page 34: ...5 Zinc Hex Pkg of 100 3 30 1110 100 Y Cap Screw 5 16 18 x 1 2 Grade 5 Zinc Plated Hex Pkg of 50 3 30 1122 50 Y Cap Screw 1 4 20 x 3 8 Grade 5 Zinc Hex Pkg of 25 3 30 1106 25 Y Cap Screw 5 16 18 x 3 4...

Page 35: ...In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distrib...

Page 36: ...ED ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surf...

Page 37: ...Save These Instructions Harman TL2 0 Owner s Manual_R20 2011 ___ 09 15 3 90 08560 Service Maintenance Log Date Of Service Performed By Description Of Service...

Page 38: ...________________________________________________________________________________ ________________________________________________________________________________ _____________________________________...

Reviews: