10
TL2.0 Woodburning Stove
Dry Seasoned Wood Only!
Save These Instructions
Harman® • TL2.0 Owner's Manual_R20 • 2011 -___ • 09/15
B. Clearances To Combustibles
*D
B
C
A
A
B
B
A
Vertical Venting Configuration
Location
Single-Wall Pipe
Double-Wall Pipe
A
Unit to Side Wall
14" / 356mm
14" / 356mm
B
Unit to Back Wall
13" / 330mm
7" / 178mm
C
Vent Pipe to Side Wall
24" / 640mm
24" / 610mm
D
Vent Pipe to Back Wall
18" / 457mm
12" / 305mm
Corner Installation
E
Corner to Adjacent Wall
16" / 406mm
10" 254mm
F
Connector to Wall
22-1/2" / 457mm
16-1/2" / 419mm
For clearance reduction methods, refer to NFPA 211 or Local Codes
Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel–Burning Appliances" for clearance from the top of the
unit to ceiling.
This unit was not tested for installation into an Alcove. Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel–
Burning Appliances".