* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.

© 2022 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380      Ph. 800-750-2723

THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.

Owner’s Instruction and Operation Manual

U.S. Environmental Protection Agency

Certified to comply with 2020 particulate 

emissions standards.

SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For 
your  safety,  follow  the  installation  instructions.  Never  use  make-shift  compromises 
during  the  installation  of  this  heater.  Contact  local  building  or  fire  officials  about 

permits, restrictions and installation requirements in your area. NEVER OPERATE THIS 
PRODUCT WHILE UNATTENDED.

CAUTION!  Please  read  this  entire  manual  before  you  install  or  use  your  new  room 

heater. Failure to follow instructions may result in property damage, bodily injury, or 

even death. Improper Installation Will Void Your Warranty!

Save These Instructions In A Safe Place For Future Reference.

 CALIFORNIA PROPOSITION 65 WARNING:

This product can expose you to chemicals 

including carbon monoxide, which is known to the 

State of California to cause cancer, birth defects, 

and/or other reproductive harm. For more 

information, go to 

www.P65warnings.ca.gov

853932B-

3005L

VG5722

R

Report #: F22-782

Certified  to  ASTM  E1509-12  (2017), 

and Certified to ULC-S627-00-REV1

Mobile Home Approved

Model Number:

Summary of Contents for VG5722

Page 1: ...r fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warranty Save These Instructions In A Safe Place For Futu...

Page 2: ...ood pellet fuel this heater has been shown to deliver heat at a rate of 32 591 to 13 640 Btu hr This heater achieved a particulate emissions rate of 1 5 g hr when tested to method ASTM E 2779 EPA Method 28R and 76 efficiency INTRODUCTION Heating Specifications Fuel Burn Rate lowest setting 2 1 5 lbs hr 0 97 2 26 kg hr Pellet size may effect the actual rate of fuel feed and burn times Fuel feed rat...

Page 3: ..._________________________________________ If no Date of inspection of existing venting system ___________________________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as per Installation Instructions Confirm proper placement of internal parts Check soundness of door gasket and door seals Confirm clearances to combustibles as per installation instructions in...

Page 4: ...URGE PROTECTOR IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONTOF OR OVERTHE HEATER DO NOT ROUTE THE CORD IN FOOTTRAFFIC AREAS OR PINCH THE CORD UNDER FURNITURE CAUTION BURNING FUEL CREATES CARBON MONOXIDE AND CAN BE HAZARDOUS TO YOUR HEALTH IF NOT PROPE...

Page 5: ...the top of the stove There will be two wire harnesses as shown 2 Unpack the top mount controls and ensure that the wiring harness shown is attached securely 3 Connect the factory installed wiring harnesses to the control panel as shown 4 Secure the control panel to the top of the stove with two sheet metal screws INSTALLATION ...

Page 6: ...in front 6 153 mm on each side and 1 26 mm behind the stove Floor protection must extend under and 2 51 mm to each side of the chimney tee for an interior vertical installation A Floor Protector of 1 26 mm thick is recommended for this installation D B C B A A Rear through wall 1 25 mm B Side 6 152 mm C Front 6 152 mm D Rear interior vertical 2 50 mm CLEARANCES Your pellet stove has been tested an...

Page 7: ... or 4 inch PL Vent and must extend a minimum or 36 914 mm above the roof line of the mobile home and must be installed using a certified ceiling fire stop and rain cap When moving your mobile home all exterior venting must be removed while the mobile home is being relocated After relocation all venting must be reinstalled and securely fastened Outside Air is mandatory for mobile home installation ...

Page 8: ...t include a clean out tee to enable collection of fly ash and to permit periodic cleaning of the exhaust system 90 degree elbows accumulate fly ash and soot thereby reducing exhaust flow and performance of the stove Each elbow or tee reduces draft potential by 30 to 50 All joints in the vent system must be fastened by at least 3 screws and all joints must be sealed with Hi Temp RTV silicone sealan...

Page 9: ...Locate your pellet stove in a location which meets the requirements of this manual but in an area where it does not interfere with the house framing wiring etc 2 Install a non combustible hearth pad underneath the pellet stove This pad should extend at least 6 152 mm in front of the unit 3 Place the pellet stove approximately 15 381 mm away from the interior wall 4 Locate the center of the exhaust...

Page 10: ...t is recommended that the installation be taller than 3ft 0 91m to get above the snowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached With this installation you have to be aware of the snowdrift line dead grass and leaves We recommend a 3ft 0 91m minimum vertical rise on ...

Page 11: ...e conform to any local building codes or regulations having jurisdiction before you have a qualified installer proceed with this installation WARNING You may want to locate any utilities or obstacles inside the wall before attempting this install Make sure to keep in mind your unit s clearance requirements 1 Mark the area and then cut the wall for vent installation if needed 2 Install the wall thi...

Page 12: ... range 5 C F Button The C F button changes the two digit display from degrees Celsius to degrees Fahrenheit MODE M T BUTTON The Mode of the stove can be switched between manual and controlled with a Thermostat Separate LEDs to the left of the two digit display indicate the mode of operation Manual or T Stat The stove has to be in normal operation to be switched from Manual to T Stat mode Manual mo...

Page 13: ...n or are wet will result in reduced performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could result in a house fire Do not over fire or use volatile fuels or combustibles doing so may cause a personal and property damage hazards THIS STOVE IS APPROVED FOR BURNING PEL...

Page 14: ...lly shut down and turn off before you will be able to restart the stove IGNITOR 1 Fill hopper and clean burn pot 2 Press the On Off button Make sure the green light comes on 3 Adjust the feed rate to the desired setting by pressing the Heat Level Advance button If the fire doesn t start in 12 minutes press On Off wait a few minutes clear the burn pot and start the procedure again OPENING DOOR CAUT...

Page 15: ...e will shut down and show E2 on the two digit display The stove has to fully shut down before restarting INTERIOR CHAMBERS Burn Pot Periodically remove and clean the burn pot and the area inside the burn pot housing In particular it is advisable to clean out the holes in the burn pot to remove any build up that may prevent air from moving through the burn pot freely Heat Exchanger There are two cl...

Page 16: ... service It is also recommended that before each heating season the entire system be professionally inspected cleaned and if necessary repaired To clean the chimney disconnect the vent from the stove FLY ASH This accumulates in the horizontal portion of an exhaust run Though non combustible it may impede the normal exhaust flow It should therefore be periodically removed ASH REMOVAL DISPOSAL CAUTI...

Page 17: ... making sure the gasket runs the full perimeter of the glass edge 5 Re install the retainer and eight nuts and rope gasket using high temperature silicone to adhere the gasket to the door 6 Never use substitute materials for the glass DO NOT abuse the door glass by striking slamming or similar trauma Do not operate the stove with the glass removed cracked or broken FALL START UP Prior to starting ...

Page 18: ...stove first when possible The convection blower is overheating and tripping the internal temperature shutoff Clean any dust off of the windings and fan blade If oiling the blower does not help the blower may be bad The stove is being left on the highest setting for extended periods of time If operating the heater on the highest heat setting the room temperature could increase enough and lead to po...

Page 19: ...ires to the air switch Combustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should be a full current If there is power the blower is bad If there is not make sure the control board is sending power to the air switch Control board not sending power to combustion blower If there is...

Page 20: ...g the auger pin then remove the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the lower bearing of the auger Pull the auger out of the tube to free the jam The auger motor has failed Remove the auger motor from the auger shaft and try to run the unit If the mo...

Page 21: ...el and auger motor for secure connections Use a continuity tester to test the hopper safety switch replace if necessary The auger shaft is jammed Start by emptying the hopper Then remove the auger motor by removing the auger pin Remove the auger shaft inspection plate in the hopper so that you can see the auger shaft Gently lift the auger shaft straight up so that the end of the auger shaft comes ...

Page 22: ... Smell Coming Back Into The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that has a temperature rating on 500 degree F or higher Also seal joints with UL 181 AP foil tape Also make sure the square to round adapter piece on the combustion blower has been p...

Page 23: ... shaft inspection plate in the hopper so that you can see the auger shaft Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing Next remove the two nuts that hold the top auger biscuit in Then rotate the bottom end of the auger shaft up towards you until you can lift the shaft out of the stove After you have removed the shaft inspect it...

Page 24: ...t is made from a different type of wood softwood vs hardwood Different woods have different characteristics when being burned High Limit Switch Keeps Tripping Possible Causes Possible Remedies Unplug stove first when possible The convection blower is overheating and tripping the internal temperature shutoff Clean any dust off of the windings and fan blades If oiling the blower does not help the bl...

Page 25: ...e ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached to the back of the unit Other information that may be needed would be the part number and part description of the item s in question Part numbers and descriptions can be found in the Repair Parts section of this manual Once th...

Page 26: ...ass 1 3 88324 1 Rope Gasket 1 4 893629 Burnpot Assembly 1 5 80780 IR Remote 1 6 80455 High Temp Snapdisc 1 7 80886 Circuit Board Assy 1 8 88351 Channel Gasket 1 9 88118 Ignitor Flange Gasket 1 10 80869 Ceramic Ignitor 1 11 80549 Pressure Switch 1 12 80867 Distribution Blower 1 13 88106 Distribution Blower Gasket 1 14 80866 Drive Motor 1 5 RPM CCW 1 15 80610 POF Snapdisc 1 16 88100 Exhaust Blower G...

Page 27: ...___ Engineer Name ______________________________________ License No _________________________________________ Company ____________________________________________ Telephone No _______________________________________ Stove Inspected Chimney Swept Items Replaced ______________________________________ Service 02 Date ________________________ Engineer Name ______________________________________ Licens...

Page 28: ...28 2022 United States Stove Company NOTES ...

Page 29: ... 2022 United States Stove Company 29 NOTES ...

Page 30: ...________________ Service de 07 Date _______________________ Nom de l ingénieur __________________________________ N de licence _______________________________________ Compagnie _________________________________________ N de téléphone ____________________________________ Poêle Inspecté Cheminée balayée Articles Remplacé __________________________________ Service de 02 Date _______________________ N...

Page 31: ... 893629 Assemblage Burnpot 1 5 80780 Ir à distance 1 6 80455 Snapdisc à température élevée 1 7 80886 Assy de carte de circuit imprimé 1 8 88351 Joint de canal 1 9 88118 Joint de bride d igniteur 1 10 80869 Ignitor céramique 1 11 80549 Pressostat 1 12 80867 Souffleur de distribution 1 13 88106 Joint de soufflante de distribution 1 14 80866 Moteur d entraînement 1 5 RPM CCW 1 15 80610 POF Snapdisc 1 16 ...

Page 32: ...e modèle et le numéro de série de cet appareil Cette information se trouve sur l étiquette de certification apposée à l arrière de l appareil D autres informations qui pourraient être nécessaires sont le numéro de pièce et la description de l article en question Les références et les descriptions se trouvent dans la section Pièces de réparation de ce manuel Une fois ces informations recueillies vo...

Page 33: ...MENT La marque ou le lot de granulés utilisés est peut être de mauvaise qualité Si possible essayez une autre marque de granulés Essayez aussi une marque composée d un autre type de bois résineux plutôt que feuillus Des bois différents présentent des caractéristiques différentes qui affectent la combustion L interrupteur de surchauffe se déclenche tout le temps Causes possibles Solutions possibles...

Page 34: ...etirez le moteur de l arbre de la tarière et essayez de le faire fonctionner Si le moteur tourne c est l arbre qui est coincé sur quelque chose Si le moteur ne tourne pas il est défectueux Tarière bloquée Commencez par vider la trémie Puis retirez le moteur de la tarière en retirant la goupille de la tarière Retirez la plaque d inspection de l arbre de la tarière dans la trémie pour pouvoir examin...

Page 35: ...nt est défectueux Le tableau de commande n envoie pas de courant à l allumeur Vérifiez la tension qui arrive à l allumeur lors du démarrage Ce doit être la tension nominale Si la tension est inférieure à la valeur nominale vérifiez le câblage Si le câblage est bon c est le tableau qui est défectueux UNE ODEUR DE FUMÉE EST REFOULÉE DANS LA PIÈCE Causes possibles Solutions possibles Débranchez le po...

Page 36: ...moteur de la tarière Utilisez un testeur de continuité pour tester l interrupteur de sécurité de la trémie remplacer le si nécessaire L arbre de la tarière est coincé Commencez par vider la trémie Puis retirez le moteur de la tarière en retirant la goupille de la tarière Retirez la plaque d inspection de l arbre de la tarière dans la trémie pour pouvoir examiner l arbre de la tarière Soulevez légè...

Page 37: ...cez par vider la trémie Retirez ensuite le moteur de la tarière en retirant la goupille de la tarière puis retirez les deux boulons qui fixent le support de tarière au tube de tarière Vous pouvez maintenant retirer le support du tube de tarière Retirez les deux boulons du côté du tube de tarière pour déposer le roulement inférieur de la tarière Tirez sur la tarière pour la sortir du tube afin de l...

Page 38: ...pteur de débit d air Panne du ventilateur de combustion Lorsque le poêle est en marche vérifiez si le ventilateur de combustion est en fonctionnement Sinon vérifiez l alimentation électrique du ventilateur de combustion Ce doit être la tension nominale Si l alimentation électrique est bonne c est le ventilateur qui est défectueux Si l alimentation est absente reportez vous au point No 8 Le tableau...

Page 39: ...Le ventilateur de convection surchauffe et déclenche l arrêt de température interne Enlevez la poussière des bobinages et pales de ventilateur Si le graissage du ventilateur ne suffit pas il se peut que le ventilateur soit défectueux Le poêle est demeuré sur le réglage le plus élevé pendant de longues périodes En cas d utilisation du poêle sur le réglage de chauffage le plus élevé il se peut que l...

Page 40: ...neusement les morceaux de verre détachés du cadre de la porte 4 Remplacez la vitre et le joint en vous assurant que le joint parcourt tout le périmètre du bord du verre 5 Réinstaller le dispositif de retenue et les huit écrous et le joint de corde à l aide de silicone haute température pour faire adhérer le joint à la porte 6 N utilisez jamais de matériaux de substitution pour le verre NE PAS malt...

Page 41: ...Pour nettoyer la cheminée déconnecter l évacuation du poêle CENDRES VOLANTES Elles s accumulent dans la portion horizontale du conduit d évacuation Bien qu elles ne soient pas combustibles elles peuvent gêner le flux normal d évacuation Elles doivent donc être périodiquement éliminées ENLÈVEMENT ET ÉLIMINATION DES CENDRES AVERTISSEMENT LAISSEZ LE POÊLE REFROIDIR AVANT D EFFECTUER TOUT ENTRETIEN OU...

Page 42: ...tre redémarré CHAMBRES INTÉRIEURES Pot de combustion Retirez et nettoyez périodiquement le pot de combustion et la zone à l intérieur du boîtier du pot de combustion En particulier il est conseillé de nettoyer les trous du pot de combustion pour éliminer toute accumulation qui pourrait empêcher l air de circuler librement dans le pot de combustion Échangeur de chaleur Deux plaques de nettoyage doi...

Page 43: ...Avance du niveau de chaleur Si le feu ne démarre pas dans 12 minutes appuyez sur Marche Arrêt attendez quelques minutes dégagez le pot de combustion et recommencez la procédure OUVERTURE DE LA PORTE Si la porte est ouverte pendant le fonctionnement du poêle elle doit être refermée dans les 30 secondes sinon le poêle s éteint Si le poêle s éteint appuyez sur l interrupteur ON OFF pour le redémarrer...

Page 44: ...el inférieur à 300 parties par million Les granulés mous contenant une quantité excessive de sciure de bois en vrac qui ont été ou sont mouillés réduiront les performances Rangez vos pellets dans un endroit sec NE stockez PAS le carburant dans les dégagements d installation de l appareil ou dans l espace requis pour faire le plein et enlever les cendres Cela pourrait provoquer un incendie Ne pas t...

Page 45: ...on ou la plage de chaleur du poêle Les niveaux de production de chaleur changent progressivement sur le diagramme en barres passant du niveau 1 au niveau 5 de chauffage C Touche C F La touche C F fait passer l affichage à deux chiffres des degrés Celsius aux degrés Fahrenheit et vice versa D TOUCHE mode M T Le Mode de fonctionnement du poêle peut être Manuel ou commandé par un Thermostat Des diode...

Page 46: ...teur de 6 pouces les illustrations ci dessous ne sont que des exemples Veuillez confirmer à tous les codes du bâtiment locaux ou ragulations ayant compétence avant de demander à un installateur qualifié de procéder à cette installation AVERTISSEMENT Vous voudrez peut être localiser les utilitaires ou les obstacles à l intérieur du mur avant de tenter cette installation Assurez vous de garder à l e...

Page 47: ...fortes chutes de neige il est recommandé que l installation soit plus grand que 3 pieds 0 91 m pour obtenir au dessus de la ligne de congère Cette même installation peut être utilisée si votre chauffe eau est en dessous du niveau du sol en ajoutant simplement la section de nettoyage et tuyau vertical intérieur jusqu à ce que le niveau du sol est atteint Avec cette installation vous devez être cons...

Page 48: ...es de ce manuel mais dans une zone où il ne gêne pas la charpente de la maison le câblage etc 2 Installez un tampon de foyer non combustible sous le poêle à granulés Ce coussin doit dépasser d au moins 6 po 152 mm en face de l unité 3 Placez le poêle à granulés environ 15 po 381 mm de loin de la paroi intérieure 4 Localisez le centre du tuyau d échappement de votre unité Ce point devrait ensuite ê...

Page 49: ...nt ainsi le débit d échappement et les performances du poêle Chaque coude ou té réduit le potentiel de tirage de 30 à 50 Tous les joints du système de ventilation doivent être fixés par au moins 3 vis et tous les joints doivent être scellés avec du mastic silicone Hi Temp RTV pour être hermétiques La zone où le tuyau de ventilation pénètre à l extérieur de la maison doit être scellée avec du silic...

Page 50: ...e d un coupe feu de plafond certifié et d un chapeau de pluie Lors du déménagement de votre maison mobile toute ventilation extérieure doit être enlevée pendant le déplacement de la maison mobile Après le déplacement tous les évents doivent être réinstallés et solidement fixés L air extérieur est obligatoire pour l installation d une maison mobile Consultez la section Alimentation en air extérieur...

Page 51: ...r au moins 6 po 153 mm à l avant 6 po 153 mm de chaque côté et 1 po 26 mm derrière le poêle La protection du plancher doit s étendre sous et 2 po 51 mm de chaque côté du té de cheminée pour une installation verticale intérieure Un protecteur de plancher de 1 po 26 mm d épaisseur est recommandé pour cette installation Les installations canadiennes nécessitent 18 po 450 mm devant l unité D B C B A D...

Page 52: ...E PRISE ET NE COUPEZ PAS LA FICHE DE TERRE N ACHEMINEZ PAS LE CORDON ÉLECTRIQUE SOUS DEVANT OU SUR LE POÊLE NE FAITES PAS COURIR LE CORDON ÉLECTRIQUE DANS LES ZONES DE PASSAGE ET NE LE COINCEZ PAS SOUS LES MEUBLES ATTENTION ATTENTION LA COMBUSTION DU COMBUSTIBLE GÉNÈRE DU MONOXYDE DE CARBONE QUI PEUT S AVÉRER DANGEREUX POUR LA SANTÉ EN L ABSENCE D UNE VENTILATION APPROPRIÉE ATTENTION UN DÉTECTEUR ...

Page 53: ...s du poêle Il y aura deux faisceaux de câbles comme illustré 2 Déballez les meilleurs contrôles de montage et de veiller à ce que le faisceau de câblage illustré est fixé 3 Connecter les installés en usine faisceaux de câblage sur le panneau de commande comme indiqué 4 Fixez le panneau de commande au dessus du poêle comme indiqué Fixer avec deux vis à tôle ...

Page 54: ...non date d inspection du système de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conformément aux instructions d installation Confirmer le bon placement des pièces internes Vérifier la solidité du joint de porte et des joints de porte Confirmer les dégagements aux combustibles selon les instructi...

Page 55: ...e de Pellet peut effectuer le taux réel d alimentation en carburant et de brûler fois Taux d alimentation en carburant peut varier par autant que 20 Utiliser PFI carburant listé pour de meilleurs résultats Temps de combustion réglage le plus bas 80 hrs Capacité de la trémie 170lbs 77kg Spécifications Électriques Note électrique 110 120 volts 60 HZ 30 Amps Watts opérationnel 175 approx Watts allume...

Page 56: ...s de fortune lors de l installation de ce radiateur Contactez les responsables locaux du bâtiment ou des pompiers pour connaître les permis les restrictions et les exigences d installation dans votre région NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l intégralité de ce manuel avant d installer ou d utiliser votre nouveau radiateur Le non respect des instructions pe...