background image

III

 

  Conforming to this directive will minimise the risk of hearing damage caused 

by long listening periods. A simple rule to follow is: The longer you listen, the 

lower the average volume should be. Please take care when working with your 

audio system – if you are manipulating controls which you don’t understand 

(which we all do when we are learning), make sure your monitoring level is 

turned down. 

Remember that your ears are the most important tool of your 

trade. Look after them, and they will look after you. Most importantly: Don’t 

be afraid to experiment to find out how each parameter affects the sound;  

this will extend your creativity and help you to get the best results.

A1 

Safety Symbol Guide

 

  For your own safety and to avoid invalidation of the warranty, all text marked 

with these symbols should be read carefully.

 

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

ACHTUNG

GEFAHR: ELEKTRISCHER SCHLAG

NICHT ÖFFNEN

ATTENTION

RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

  To reduce the risk of electric shock, do not remove covers. No user-serviceable 

parts inside. Refer servicing to qualified service personnel (i.e., persons 

having appropriate technical training and experience necessary to be aware 

of hazards to which they are exposed in performing a repair action, and of 

measures to minimize the danger of themselves).

 

  The lightning flash with arrowhead symbol is intended to alert the user to the 

presence of un-insulated ‘dangerous voltage’ within the product’s enclosure 

that may be of sufficient magnitude to constitute a risk of electric shock to 

persons.

 

!

  The exclamation mark within an equilateral triangle is intended to alert the 

user to the presence of important operating and maintenance (servicing) 

instructions in the literature accompanying the appliance.

 

!

  Headphones safety warnings contain important information and useful tips 

on headphone outputs and monitoring levels. 

 

CLASS 1

LASER PRODUCT

CLASS 1

LED PRODUCT

  Assemblies or sub-assemblies of this product can contain opto-electronic 

devices. As long as these devices comply with Class I of laser or LED prod-

ucts according to EN 60825-1:1994, they will not be expressly marked on 

the product. If a special design should be covered by a higher class of this 

standard, the device concerned will be marked directly on the assembly or 

sub-assembly in accordance with the above standard.

A2 

First Aid

In Case of Electric Shock: 

  Separate the person as quickly as possible from the electric power source:

 

  •  By switching the equipment off,

 

  •  By unplugging or disconnecting the mains cable, or 

 

  •  By pushing the person away from the power source, using dry insulating 

material (such as wood or plastic).

 

  •  After having suffered an electric shock, 

always

 consult a doctor.

Warning! 

  Do not touch the person or his clothing before the power is turned off, 

otherwise you stand the risk of suffering an electric shock as well!

If the Person is Unconscious:

 

  •  Lay the person down

 

  •  Turn him to one side

 

  •  Check the pulse

 

  •  Reanimate the person if respiration is poor

 

  • 

Call for a doctor immed iately

.

Safety Information

Summary of Contents for STUDER

Page 1: ...Compact Stagebox Installation and Operating Instructions...

Page 2: ...any loss or damage resulting either directly or indirectly from use of the information contained within it Prepared and edited by Copyright by Studer Professional Audio GmbH Studer Professional Audio...

Page 3: ...When a cart is used use cau tion when moving the cart apparatus combination to avoid injury from tip over Refer all servicing to qualified service personnel Servicing is required when the apparatus ha...

Page 4: ...pment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful i...

Page 5: ...angerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation mark within an equilateral triangle is intended to...

Page 6: ...any way during operation e g by objects placed upon them placement of the unit on a soft surface or installation of the unit within a rack or piece of furniture The unit must not be heated up by exter...

Page 7: ...ided earth terminal if one or more external signals are connected to the unit see expla nation at the beginning of this paragraph B4 Electromagnetic Compatibility EMC The unit conforms to the protecti...

Page 8: ...ling can be improved by an additional conducting surface in the operator s area connected to the equipment housing e g metal foil underneath the floor covering carpet with conduc tive backing C Mainte...

Page 9: ...air By removing housing parts or shields energized parts may be exposed For this reason the following precautions must be observed Maintenance may only be performed by trained personnel in accordance...

Page 10: ...PCB 3 2 1 3 2 1 F Disposal Packing Materials The packing materials have been selected with environmental and disposal issues in mind All packing material can be recycled Recycling packing saves raw ma...

Page 11: ...suant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate ra...

Page 12: ...l maximum 10 K increase at the hot components In order to dissipate 1 kW with this admissible average heat increase an air flow of 2 65 m min is required Example Arack dissipating P 800 W requires an...

Page 13: ...rface always remains below 100 Ensure that the enclosed air is as dry as possible when powering off i e before switching off in winter aerate the room with cold dry air and remove humid objects such a...

Page 14: ...commended application temperature range is 20 C to 40 C Remove the plastic protective backing from the rear side of the clamp and apply it firmly to the surface at the desired position Allow as much t...

Page 15: ...tem and or its options at the time of delivery to the Customer but have not been developed by Studer The following conditions are applicable to programs of third parties The right to use third parties...

Page 16: ...g to the paragraph above by appropriate defense measures against unauthorized access This obligation of non disclosure is a perpetual obligation Third parties are entitled to have access to the Licens...

Page 17: ...odules 5 1 5 D21m Expansion Slots 5 2 Details 5 2 1 Front Rear View 6 2 2 AC Power Supply 6 2 3 Module Setup and Connector Details 6 2 4 GPIO General Purpose Inputs Outputs 8 3 Setup Examples 10 3 1 C...

Page 18: ...Compact Stagebox 2 Document generated 12 02 13 SW V4 1...

Page 19: ...nnected to an appropriate cable by a trained technician respecting your local regulations Refer to the Installation Operation and Waste Disposal chapter at the begin ning of this manual Earthing This...

Page 20: ...der digital mixing systems and allows connection to most popular digital formats including CobraNet Aviom A Net 16 EtherSound ADAT Livewire and RockNet A MADI recording interface may also be fitted to...

Page 21: ...r cable dual width 16 channel ADAT inputs and outputs single width 16 channel TDIF inputs and outputs dual width 16 channel Aviom A Net outputs single width 32 channel CobraNet inputs and outputs sing...

Page 22: ...e that the two cables are connected to separate phases 2 3 Module Setup and Connector Details Analog Mic Line Input Module The HQ mic line input module handles 16 microphone or line level input signal...

Page 23: ...er pair with a DIP switch on the module The factory default setting of the eight switch segments is OFF enabled In order to change the settings remove the module as described in chapter 4 S1 Bypass Ch...

Page 24: ...nding on which socket is being used For dual cable redundant operation The front panel toggle switch must be set to RED mode For additional information refer to the setup examples in chapter 3 Expansi...

Page 25: ...of the external supply voltage refer to the circuit examples below GPO Relay Contact Rating max Values Switching Power 62 5 VA 30 W Switching Voltage 50 V AC or DC Switching Current 1 A Contact Resist...

Page 26: ...see chapter 3 2 SW V4 703 and up Stagebox connected to D21m MADI card in Nano SCore integrated optical MADI I O D21m MADI card in SCore Live D21m MADI card in console extension slot D21m MADI card in...

Page 27: ...d in the DSP ses sion configuration The Vista 1 comes with several factory set configuration templates with a default of 32 input ports and 16 output ports for the D21m card slots These I O port confi...

Page 28: ...are three option buttons Ok Use for this session only and Store as new default Click on Store as new default Again after waiting for a few seconds the Surveyor icon will become green and the added ca...

Page 29: ...c Information on how to select DSP configurations can be found in the Vista 1 operating instructions manual When now patching microphone inputs from the Compact Stagebox to any of the console s input...

Page 30: ...recommended to first insert all screws only by a few turns into their threads before tightening them Connect the Compact Stagebox to the AC supply again switch it on and press the recessed RECONFIG ke...

Page 31: ...d 5 D21m I O Card Installation Safety In order to insert or replace a D21m input or output card first switch the Compact Stagebox OFF and unplug the AC supply cable s Observe the precautions for handl...

Page 32: ...0 kHz 0 dB 0 3 dB THD Noise 1 dBFS 1 kHz 90 dB 30 dBFS 20 Hz to 20 kHz 103 dB Crosstalk 1 kHz 115 dB Output Level RL 600 W globally adjustable with hardware switches steps 24 22 20 18 15 12 9 6 dBu 6...

Page 33: ...Compact Stagebox 17 Document generated 12 02 13 SW V4 1 7 1 Dimensions 177 mm 7 4 HU 483 mm 19 363 mm 14 3 2 mm 0 1 42 mm 1 7...

Page 34: ...Compact Stagebox 18 Document generated 12 02 13 SW V4 1...