Compact Stagebox
13
Document generated: 12.02.13
SW V4.1
3.2.2
Connection
Note:
The DIP switches on the MADI HD card in the Compact Stagebox must be
set to match the actual number of channels provided from and to the Stage-
box. For details, please refer to
chapter 4
below and the ‘D21m I/O System
Operating Instructions’ document, available either from www.studer.ch in
the ‘Downloads’ - ‘User Guides’ - ‘Studer D21m I/O System’ area, or on the
product disc (CD or DVD) shipped with your console.
Vista 1 is predefined for use with a Studer Compact Stagebox featuring 32
mic/line inputs and 16 line outputs. Template titles for these configurations
are, for example, ‘Vista1 Mono’, ‘Vista1 Stereo’, ‘Vista1 Surround’, ‘Vista1
FOH’, etc. If the number of I/O ports required by the Stagebox should exceed
32/16, it is recommended to use one of the DSP session configurations having
64/64 I/O available for the D21m extension slot: ‘Vista1 Monod21’, ‘Vista1
Stereod21’, ‘Vista1 Surroundd21’, etc. Information on how to select DSP
configurations can be found in the Vista 1 operating instructions manual.
When now patching microphone inputs from the Compact Stagebox to any
of the console’s input channels and pressing the
GLOBAL VIEW - MIC CTRL
key on the desk, the microphone preamp control parameters appear on the
Vistonics screen. Input gain, 48 V phantom power and the high-pass (low-cut)
filter can now be controlled remotely from the desk.
4
I/O Module Replacement
Safety
For adjustments or replacing an input or output module, first switch the
Compact Stagebox off and unplug the AC supply cable(s).
Observe the pre-
cautions for
handling devices sensitive to electrostatic discharge; also refer
to chapter D at the beginning of this manual.
•
When using an HQ mic/line input module in the Studer Compact Stagebox,
jumper J1 must not be plugged
.
•
When using a line output module in the Studer Compact Stagebox, the
output level of the analog line output module may be selected accord-
ing to your preferences b6 and +24 dBu for 0 dB
FS
(factory
default setting: +15 dBu for 0 dB
FS
). This setting is valid for all outputs
simultaneously.
Factory Default: