Compact Stagebox
5
Document generated: 12.02.13
SW V4.1
It comes complete with twin redundant power supplies, temperature-con-
trolled, low-noise fan cooling, and full LED status monitoring. An eight-
channel GPIO (general-purpose control input/output) interface is provided
as well.
1.4
Available I/O Modules
(Slots A, C, E)
•
16 × HQ mic/line inputs
•
16 × line outputs with DIP switch-selectable level
•
8 × 2-ch AES/EBU inputs with SRC (sampling rate converters), plus
8 × 2-ch AES/EBU outputs
•
4 × 2-ch AES/EBU outputs, plus 8 x line outputs with DIP switch-selectable
level
1.5
D21m Expansion Slots
(Slots K, L)
The expansion slots may be used for one (dual-width) or two (single-width)
Studer D21m I/O cards.
Analog I/O
• 8-channel line inputs
(single-width)
• 8-channel line outputs
(single-width)
• 4-channel mic/line inputs with 4 x direct outputs
(single-width)
4-channel
mic/line inputs with 4 x direct outputs
(single-width)
Digital I/O
• 8 x 2-channel AES inputs and outputs
(dual-width)
• 64-channel MADI inputs and outputs for optical/multimode fibre
(dual-
width)
or Cat5 twisted-pair cable
(dual-width)
• 16-channel ADAT inputs and outputs
(single-width)
• 16-channel TDIF inputs and outputs
(dual-width)
• 16-channel Aviom A-Net
®
outputs
(single-width)
• 32-channel CobraNet
®
inputs and outputs
(single-width)
• 16-channel SDI embedder and/or deembedder
(single-width)
• 16-channel Dolby
®
E/Digital decoder
(single-width)
• 2 x 16-channel Livewire
®
inputs and outputs
(single-width)
• 64-channel RockNet
®
inputs and outputs
(dual-width)
• 64-channel EtherSound
®
inputs and outputs
(dual-width)
.
The EtherSound card is available from a third-party manufacturer/distribu-
tor only. Contact www.digigram.com for EtherSound® options.
For more information on the D21m system please refer to the ‘D21m I/O
System Operating Instructions’ document available from www.studer.ch in
the ‘Downloads’ - ‘User Guides’ - ‘Studer D21m I/O System’ area.
2
Details
The Compact Stagebox contains the D21m MADI HD card providing the con-
nection to the console, three slots for input and/or output modules (A/C/E),
and two slots for optional D21m I/O modules (K/L). These labeling conven-
tions will also be used when patching the connectors to input channels or
output busses of the console.
The console requires the addition of a D21m MADI card (refer to
chapter 3
)