6.5.3
6.5.3: INPUT CHANNEL > DYNAMICS > DE ESS
®
Vi3000 USER MANUAL
6.5.3: INPUT CHANNEL > DYNAMICS
De-Esser Sensi-
tivity
Field / Group: SENS
Range Low
Range High
Adjust the sensitivty of
the De-esser process.
0%
100%
De-Esser In
Field / Group: DEES
Inactive
Active
Activates the De-esser
process
Out
In
De-Esser Range
Field / Group: RNG
Range Low
Range High
Adjusts the De-esser
attenuation.
The maximum amount by which the signal in the 'Ess'
band is attenuated when the DeEsser is activated.
-18dB
0dB
Ess Band Solo
Field / Group: RNG
Inactive
Active
Solo the De-esser
dynamic filter.
Helps pinpoint the 'Ess band' most suited to the current
signal.
Off
Solo
De-Ess Filter
Frequency
Field / Group: FREQ
Range Low
Range High
Adjust the centre
frequency of the De-ess
dynamic filter.
20Hz
20kHz
External Key
Assign
Field / Group: MODE
Inactive
Active
x
Activate the External
Key Assign screen in
the main Vistonics touch
sreen panel.
All external I/O options for the external key become
available for selection.
+
-
DE-ESS Function
The de-esser is a dynamically controlled filter normally used to reduce the sibilance (‘sss’ components) in
a singer’s voice. If the de-esser is active, the signal level will be reduced only in the band set by the filters,
when the signal in this band exceeds the required threshold.
Summary of Contents for SoundCraft Vi3000
Page 1: ...User Guide v1 4...
Page 14: ...Vi3000 USER MANUAL 3 0 3 3 0 QUICK START 3 0 QUICK START Inputs Controls Input Channel Access...
Page 16: ...Vi3000 USER MANUAL 3 0 5 3 0 QUICK START 3 0 QUICK START Outputs Control...
Page 18: ...Vi3000 USER MANUAL 3 0 7 3 0 QUICK START 3 0 QUICK START Copy Paste Move LIbrary...
Page 20: ...Vi3000 USER MANUAL 3 0 9 3 0 QUICK START 3 0 QUICK START Main Menu System Lexicon FX...
Page 26: ...5 0 5 0 Operations Overview Vi3000 USER MANUAL 5 0 Operations Overview 5 0 Operations Overview...
Page 68: ...Vi3000 USER MANUAL 7 0 7 0 OUTPUTS 7 0 OUTPUTS Outputs Auxilliaries Groups and LCR Mix busses...