HPX-PA-HVI High Voltage Isolator
25
HPX-1600 Retractable Connection Port
HPX-PA-HVI High Voltage Isolator
Overview
The HPX-PA-HVI High Voltage Isolator (FG559-33) is designed to be installed in the HPX-1600-xx-xx Hydraport Retractable
Connection Port to separate the AC Mains Power from low-voltage, secondary-circuits (FIG. 29).
WARNING: If AC Mains Power Outlets are to be used in the HPX-1600 this item must be installed in order to maintain Product
Safety Certifications. Failure to install this item properly may void Product Safety Certifications.
Product Specifications
Installation
WARNING: Only a professional, AMX-qualified installer should perform this installation. Installation must conform to all local
codes. This product may not be installed by the end-user.
Tools Required
Scissors
Step 1 - Install Low-Voltage Secondary Circuit Modules
NOTE:
All low-voltage, secondary-circuit modules must be installed above the AC Mains Power Outlets and Circuit Breakers in the
HPX-1600.
Install all low-voltage, secondary-circuit modules into the HPX-1600 Hydraport Base Assembly from the bottom of the unit
according to the instructions supplied with the HPX-1600 and or low-voltage, secondary-circuit modules. For more information
refer to the HPX-1600 Operation Reference Guide.
Position the cables coming from the low-voltage, secondary-circuit modules along the sides of the aluminum chassis. These cables
will pass along the outside of the folded High Voltage Isolator and exit the unit through the square openings in the bottom cover.
Step 2 - Fold the High Voltage Isolator
Use the score lines on the High Voltage Isolator to fold the paper into the shape shown in Figure 1. Interlock the two tabs and slots
at the top of the part with the square tab (back) folded inside the interlocking tabs (sides).
Pre-crease the folds as required to achieve a sharp, square fold.
FIG. 29
HPX-PA-HVI (Folded for Installation)
HPX-PA-HVI Specifications
Material:
Vulcanex ®, Vulcanized Fiber
Thickness:
0.4mm (0.016in)
Dielectric Strength:
300V/mil (4,800V)
Included Accessories:
Installation Guide