Installing the HPX-1600
8
HPX-1600 Retractable Connection Port
Step 4 - Insert the Modules
IMPORTANT:
See Step 4.6 for the installation of High Voltage Isolators (HPX-PA-HVI) These Isolators must be installed properly to
maintain product safety certifications.
NOTE:
All Low-Voltage, Secondary-Circuit (LVSC) Modules must be installed above the AC Power Outlets and Circuit Breaker Modules
in the HPX-1600 Base Assembly. The LVSC Modules will therefor be installed first.
1.
Latch the system in the closed (down) position.
2.
Place the HPX-1600 Base assembly upside down on a suitable surface to ensure the top cover is not scratched.
3.
Remove the four Mounting Screws that secure the Bottom Cover to the aluminum frame, and remove the bottom cover.
FIG. 9
Installing the Bottom Cover
Bottom Cover
(4) mounting screws