Installing the HPX-1600
18
HPX-1600 Retractable Connection Port
Step 9 - Install Power Cord (If Required)
If AC power modules are to be used in International models (FG550-BL, FG550-SL), install a suitable 14AWG power cord into the
provided IEC 320 C14 socket.
North American models (FG550-01-BL, FG550-01-SL) include a pre-attached power cord with metal retention bracket. If this
bracket has been removed during installation, reinstall it at this time. The metal retention bracket is required to maintain North
American Product Safety Certifications.
Fold the power cord back 180 degrees, and secure it to the far side of the bottom cover using the supplied wire ties. (FIG. 21).
NOTE:
Insure the resulting service loop is tight enough so that it does not rub the shields when the unit moves up and down.
FIG. 21
Installing the Power Cord
Power Cord
AC Power Socket
#4 Plastite screws
(provided)