HARDY MANUFACTURING CO., INC (MODEL KB165) PAGE 34
10-2 Low Water Float Switch (continued)
Step #
Operation Description
Visual Aids/Comments
5
Apply pipe joint compound liberally around the threads of the
switch. Using an adjustable wrench or other suitable tool install
the switch in the tank. Do not overtighten. Make sure the switch is
oriented with the arrow pointing down.
6
Connect new switch wiring to existing wiring using suitable wire
nut.
7
Reconnect power to furnace. On models with the automatic water
fill option allow the unit to fill above the float switch. If the
automatic water fill and low water indicator does not turn on, or if it
turns on but does not shut off when the water reaches the correct
level the switch is possibly not oriented correctly.
!
Hazardous Voltage! Disconnect Power to
Heater prior to performing this
maintenance operation.