HARDY MANUFACTURING CO., INC (MODEL KB165) PAGE 18
Existing
Boiler
Heat
Zone
Heat
Zone
Existing
Pump
Heat Exchanger
Close this valve
Heater with Hull and stacks
removed to show connections.
Hardy
P/N 300.01
40 Plate Heat
Exchanger
with 1" fittings
SECTION IV
CONNECTION TO HYDRONIC HEATING SYSTEMS (BASEBOARD)
4-1 Connection to Hydronic System
This unit must be wired by a qualified electrician in
accordance with the National Electrical Code.
The preferred method for connecting the Hardy KB165 Hydronic Heater to an existing
hydronic system is by installing a p/n 300.01 (40 plate heat exchanger w/ 1” fittings)
into the return line of the existing boiler system.
Run 2 -
1” potable hot water lines from the wood heater to the existing hydronic system.
Connect these lines to the plate heat exchanger so that the water flow of the wood
heater is opposite of that from the existing hydronic system.
1
2
Taco 009
Taco 008
Return
Supply