HARDY MANUFACTURING CO., INC (MODEL KB165) PAGE 29
9-1
TROUBLE SHOOTING GUIDE
(CONTINUED)
Problem
Causes
Solutions
Moisture in firebox
To wet of wood being burned
Burn 30% or less moisture wood
To much wood in firebox
Fill the heater with the proper amount of wood
for your application
Coal bed burning out
Maintain a proper level coal bed
Coal bed burning out To large of wood
Burn smaller wood so the coal bed will be
replenished
Wood is rotted
Rotted wood will not form a coal bed so proper
wood needs to be burned
Burning soft wood
Soft wood will not form a coal bed, you can mix
soft wood with hardwod or either burn the right
moisture hardwood
Unit smokes
Clean primary and secondary air tubes in the air
volume box
Make sure the air holes in the primary air tube
are open
Perform the weekly maintenance (section 7)
Unit is dirty
Perform weekly maintenance (section 7)
Combustion blower
Clean blower wheel for any dirt buildup
Verify that solenoids are working when power is
applied
Change out solenoid if powered up and not
operating
Air leakage
Check and seal any leakage around the air
volume box
Bad air volume box gasket
Inspect the foam gasket and replace as needed
Improper air (stopped up)
Damper solenoids