background image

 

 

 

Installation and Operating 

Instructions 

 

 

 
 

 

 

 

Salamander Eco Stove 

Model 1901 eco 

 

 
 

Installation and operating instructions for the Salamander Eco  

model 1901 eco 

(Ref 1901 eco Dec 2019) 

 

      Section 

 

 

Contents    

               

 

 

 

1  

Important information about installing and 

 

using the stove 

 

 

 

 

 

 

 

 

2  

Unpacking 

 

   

 

 

 

3  

Assembly 

 

 

 

 
4  

Components   

 

 

 
5  

Installation 

 

 

 

 

 
6  

Operating instructions 

 

 

 

 

   

6.1   Fuel   

   

6.2

   

Before lighting 

   

6.3   Air Controls 

   

6.4   Lighting a wood fire 

   

6.5   Lighting a solid fuel fire  

   

6.6   De-ashing the stove 

 
7  

Guidance on safe operation   

 

 

 

  Maintenance   

 

 

 

 

 
9  

Fault finding      

 

 

 

 
10 

Spare parts 

 

 

 

 

 

 
11 

Salamander eco performance results 

 
 
 
   
 
 
 
 

Summary of Contents for 1901 eco

Page 1: ...Contents 1 Important information about installing and using the stove 2 Unpacking 3 Assembly 4 Components 5 Installation 6 Operating instructions 6 1 Fuel 6 2 Before lighting 6 3 Air Controls 6 4 Ligh...

Page 2: ...n or near the stove The stove must NOT be installed into a chimney that serves any other appliance and is suitable for intermittent burning There must be a suitable air supply into the room where the...

Page 3: ...tove swap the collar for the blanking plate on the back before assembling the firebox as described below 3 1 Lay the stove carefully on its side and attach one leg to each corner of the base using the...

Page 4: ...earance is left at the back and sides for maintenance and to allow air to circulate around the stove 5 4 Floor National and local building regulations must be complied with when considering the floor...

Page 5: ...times a new stove is used the fire should be kept to a moderate size and not fired vigorously 6 3 Air Controls The Salamander Eco is fitted with three air controls PRIMARY AIR CONTROL Located on the...

Page 6: ...w fuel charge will ignite in a reasonable period If there are too few embers in the fire bed add suitable kindling to prevent excessive smoke Remember When opening the door always open gently for the...

Page 7: ...be tempted to overfill the firebox and risk fuel falling onto the glass or out the fire as the door is opened OVERFUELLING CAN ALSO CAUSE EXCESS SMOKE Close the door Once the new fuel is burning full...

Page 8: ...to keep a bed of ash about 1cm thick on the grate Cleaning the stove Clean the outside of the stove with a soft brush Regularly remove and clean the baffle and back and side air bricks of soot and de...

Page 9: ...list of available spares with prices go to www salamanderstoves com 11 Salamander Eco Stove Performance Results Wood Logs Results 0 80 hour refuels Parameter A19 135 1 A19 135 2 A19 135 3 Mean Test du...

Page 10: ...CE Plate...