Страница 1: ...An der Bundesstraße 2 49733 Haren Ems Germany Tel 49 0 5932 7334784 info globe fire de User s manual Comet ...

Страница 2: ...e manuel The connection of more stoves to one chimney is permitted Approved German tests and CE mark gem Art 15a B VG Ö Norm Tests of the city of München Regensburg Stuttgart and Aken DIN plus and also Luftreinhalte Verordnung Switzerland 1 2 BimschV Globe fire Type Dust in Mg on 13 O2 33 mg Nm Efficiency 80 7 40 cm 20 cm 80 cm Comet 1017 6 12 kW 8 kW Wood Coal RRF 40071331 Values converted 21 mg ...

Страница 3: ... hot approx 15 30 minutes close the grid Add further wood using 1 2 or 3 logs Make sure the wood has a real glow of flames before doing this to prevent smoke in the room Congratulations with your new Globe Fire stove Cast iron stoves have a long tradition Our business is in its 5th generation of development and production of stoves insert fires and cookers Our models are all made of a high quality...

Страница 4: ...e regulated by the revolving grid and the primary secondary air regulator Do not close the primary secondary air regulator before the wood has burnt to a glow and the flames are no longer visible In houses where air supply necessary for the fire to burn is taken from the room there should be a sufficient supply of fresh air The ash door should always remain closed when the fire is burning If the d...

Страница 5: ...al ventilation system To ensure your chimney has the correct measurements it is possible to measure it Ask your chimney sweeper for advice Before placing the stove into position check to see if the floor can take the weight When in doubt place the stove on a large slab of stone or marble to divide the weight 2 GENERAL FIRE SAFETY INSTRUCTIONS During wood burning high temperatures are reached make ...

Страница 6: ...ted with the primary secondary regulator Do not close up completely while flames are visible This is to avoid smoke entering the room Stay with the stove until burning well If the fire has been started well the stove should remain quite clean Wait until the wood has to a glow before putting on more logs 5 GLOBE FIRE RECOMMENDATIONS LIGHTING THE FIRE ON PAGE 12 burnt 6 AIR SUPPLY Always make sure t...

Страница 7: ...E FIRE IN THE AUTUMN AND SPRING In these seasons of the year when the outside temperature is higher your chimney may not have a good chimney draught and the smoke will not be sucked out enough In this case it is recommended to use a lot of dry wood three quarters full not older than 6 years By lighting for the first time also when the temperature is not so high follow Globe fire recommendations li...

Страница 8: ...electrician 12 FIRE SAFETY DISTANCES Furniture and flammable wall The distance from the back of the stove is 20 cm From both sides 40 cm From the glass 80 100 cm Floor A flammable floor carpet wood etc must be protected by a fireproof plate that is 30 cm wider on both sides and at least 50 cm in front Each type of stove may have different regulations The distances required for your stove are are f...