5 - Operation
46
External Filling Device (optional)
The External Filling Device is operated as follows:
1.
Remove cover and connect suction hose to Suction Manifold.
2.
Open the agitation valve, turn pressure valve to ”TurboFiller”, and
close the suction valve.
3.
Open the TurboFiller lid and activate
.
4.
Turn handle on External Filling Device valve towards Filling Device.
5.
Engage diaphragm pump and set P.T.O. revolutions at 540 r/min.
6.
The tank is now filled with water. Keep an eye on the liquid level
indicator.
7.
Turn handle on Suction Manifold away from Filling Device to
discontinue filling process. Then disengage pump.
8.
Deactivate
and close the TurboFiller lid.
9.
Disconnect suction tube and replace cover.
10.
Turn the suction valve to “Main tank”.
11.
Close the agitation valve if not necessary.
€
DANGER! Avoid contamination or personal injury. Do not open suction valve towards Suction Filling Device unless
pump is running and filling hose is connected. If this valve is opened without pump running, liquid will stream out
of the coupler.
±
WARNING! Do not leave the sprayer whilst filling the tank and keep an eye on the level indicator in order NOT to
overfill the tank.
μ
ATTENTION! Observe local legislation regarding use of filling device. In some areas it is prohibited to fill from open
water reservoirs (lakes, rivers etc.). It is strongly recommended only to fill from closed reservoirs (mobile water tanks
etc.) to avoid contamination.
Summary of Contents for RANGER EAGLE
Page 8: ...1 EC Declaration 8 ...
Page 12: ...2 Safety notes 12 ...
Page 26: ...3 Description 26 ...
Page 40: ...4 Sprayer setup 40 ...
Page 60: ...5 Operation 60 ...
Page 84: ...6 Maintenance 84 ...
Page 95: ...8 Technical specifications 95 Charts Boom hydraulic Z Boom hydraulic Y ...
Page 96: ...8 Technical specifications 96 ...
Page 100: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...