6 - Maintenance
72
Cone check/renewal for EVC distribution valve
Periodically check the distribution valves for proper sealing. Do this by
running the sprayer with clean water and open all distribution valves.
Cautiously remove the clip (A) and pull out the hose (B) for the return
line. When the housing is drained, there should be no liquid flow
through the return line.
If there is any leakage, the valve cone (E) must be changed.
1.
Remove the clip (C)
2.
Lift the motor housing off the valve housing.
3.
Unscrew the screw (D) and replace the valve cone (E).
4.
Reassemble in reverse order.
Level indicator adjustment
The level indicator reading should be checked regularly. When the tank is empty, the float should lie on the stop pin (D) of
the rod, and the O-ring on the indicator should be positioned at the top position line (A).
If any deviation is found, do:
1.
Pull out the plug (B).
2.
Loosen screws (C).
3.
Adjust the length of the cord until it reads correctly.
4.
Push plug (B) back in place.
÷
NOTE! For best accuracy adjustment shall be done with the sprayer attached to the tractor normally used.
Level indicator wire renewal
If the wire on the level indicator has to be changed, the float guide pole is removed:
1.
Remove the tank drain valve (see paragraph “Drain valve seal renewal”) and loosen the fitting holding the pole in
position.
2.
Pull the pole down through the drain valve hole till it is free in the top of the tank.
3.
The pole can now be taken out of the tank through the filling hole.
€
DANGER! Do not enter the inside of the tank - the parts can be changed from the outside of the tank!
Summary of Contents for RANGER EAGLE
Page 8: ...1 EC Declaration 8 ...
Page 12: ...2 Safety notes 12 ...
Page 26: ...3 Description 26 ...
Page 40: ...4 Sprayer setup 40 ...
Page 60: ...5 Operation 60 ...
Page 84: ...6 Maintenance 84 ...
Page 95: ...8 Technical specifications 95 Charts Boom hydraulic Z Boom hydraulic Y ...
Page 96: ...8 Technical specifications 96 ...
Page 100: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...