5 - Operation
104
TurboFiller Rinsing
÷
NOTE! It is important to suck from the rising tank or an external
tank with clean water.
Rinse the TurboFiller and chemical containers as follows:
Cleaning empty containers - TurboFiller lid is open
1.
Put container over the rotating flushing nozzle in the middle of the
TurboFiller, so that the nozzle is inside the container.
2.
Simultaneously press the Chemical Container Cleaning lever and
the TurboFiller suction valve. This rinses the chemical container
with the flushing nozzle, while the rinsing liquid is emptied out of the TurboFiller.
TurboFiller rinsing - TurboFiller lid is closed
1.
Close TurboFiller lid.
2.
Turn the suction SmartValve towards “Rinsing tank” or “External Filling Device”, if clean water is available here.
3.
Open the Turbo Deflector Valve
for 1 minute to get plenty of clean water through the hoses.
4.
Simultaneously press the Chemical Container Cleaning lever and the TurboFiller suction valve. This rinses the hopper
with the flushing nozzle, while the rinsing liquid is emptied out of the TurboFiller.
5.
Rinse the hopper for 30-40 seconds.
6.
Open the lid to inspect if the TurboFiller is empty. If not, close the lid again and press the TurboFiller suction valve, until
the TurboFiller is empty.
7.
After the last flushing, the TurboFiller suction valve must be open for at least 20 seconds, after the rinse water is no
longer visible in the hopper, in order to completely empty the transfer hoses into the main tank.
ATTENTION! The TurboFiller needs to be cleaned thoroughly after finishing spraying. This is to ensure that it is clean,
before spraying other crops that may be sensitive to the chemicals just used. See the section “Cleaning” on page 127
for details.
Agitation Before Resuming a Spray Job
If a spray job has been interrupted for a while, severe sedimentation may
occur depending on the chemicals being used. Before resuming the
spray job, it might be necessary to agitate sediment material.
1.
Turn the handle at the suction valve towards “Suction from main
tank”. Turn the pressure valve towards “Pressure
draining/TurboFiller” and turn the agitation valve towards
“Agitation”. Other valves are closed.
2.
Engage the pump and set PTO speed to max. 540 rpm.
3.
Agitation has started and should be continued for at least 10
minutes.
4.
The spray job can now be resumed. Turn pressure valve towards
“Spraying” and start spraying.
Summary of Contents for MEGA VPZ MASTER
Page 4: ...1 EU Declaration 4...
Page 10: ...Table of Contents 10...
Page 42: ...2 Safety Notes 42...
Page 68: ...3 Description 68...
Page 118: ...5 Operation 118...
Page 121: ...6 Maintenance 121 Lubrication Plan Boom Centre Close up of Glide Shoes to be Lubricated...
Page 172: ...8 Technical Specifications 172...
Page 176: ...Index 176...
Page 178: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 N rre Alslev DENMARK...