5 - Operation
93
Filling Through Tank Lid
Water is filled into the main tank by removing the big tank lid, which is located at the top of the sprayer. The tank lid is
accessible from the ladder. It is recommended to use as clean water as possible for spraying purposes. Always fill water
through the strainer basket to prevent foreign particles from entering the tank. An overhead tank can be used in order to
obtain high filling capacity.
±
WARNING! Do not let the filling hose enter the tank. Keep it
outside the tank, pointing towards the filling hole. If the hose is
led into the tank, and the water pressure drops at the water
supply plant, chemicals may be sucked back and contaminate
the water supply lines, supply plant and supply well.
The water supply line should be provided with a check valve as
additional safety precaution. Follow local legislation in force at
any time.
The water supply should be provided with a water meter to avoid
spillage by overfilling. Follow local legislation in force at any time.
External Filling Device
The External Filling Device (if installed) is operated as follows:
1.
Remove the cap (A) and connect a suction hose to the suction
manifold.
2.
Turn pressure valve to “Main tank”.
3.
Turn suctionvalve to “External Filling Device”.
4.
Engage the pump and set PTO revolutions at max. 540 rpm.
5.
The tank is now filled with water. Keep an eye on the liquid level
indicator.
6.
Turn handle on suction manifold away from Filling Device to
discontinue filling process. Now disengage the pump. Disconnect
suction hose and replace the cap.
€
DANGER! Prevent contamination or injury. Do not open suction
valve towards the Filling Device, unless the pump is running and
the filling hose is connected. If this valve is opened without the
pump running, liquid will stream out of the coupler.
±
WARNING! Do not leave the sprayer while filling the tank, and
keep an eye on the level indicator in order NOT to overfill the
tank.
ATTENTION! Observe local legislation regarding use of filling device. In some areas, it is prohibited to fill from open
water reservoirs (lakes, rivers etc.). It is strongly recommended only to fill from closed reservoirs (mobile water tanks
etc.) to prevent contamination.
Summary of Contents for MEGA VPZ MASTER
Page 4: ...1 EU Declaration 4...
Page 10: ...Table of Contents 10...
Page 42: ...2 Safety Notes 42...
Page 68: ...3 Description 68...
Page 118: ...5 Operation 118...
Page 121: ...6 Maintenance 121 Lubrication Plan Boom Centre Close up of Glide Shoes to be Lubricated...
Page 172: ...8 Technical Specifications 172...
Page 176: ...Index 176...
Page 178: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 N rre Alslev DENMARK...