27
HARDI
MEGA 230 / 350 CENTRIFUGAL OPERATORS MANUAL
5.4 Hydraulic Requirements with Eagle Boom
Hydraulic booms need one single outlet for the lift function of the spray
boom and one double outlet for the folding function. Note that the
hydraulic system requires an oil capacity of approximately .8 GPM (3
litres/min.)and a minimum pressure of 1,950 PSI (130 bar).
5.5 Hydraulic Hook-up
BE SURE TO HOOK UP HYDRAULIC LINES PROPERLY!
ENSURE HYDRAULIC LINES HAVE NOT BEEN DAMAGED DURING
SHIPPING.
ESCAPING HYDRAULIC FLUID UNDER PRESSURE CAN
PENETRATE THE SKIN CAUSING SERIOUS INJURY. AVOID THIS
HAZARD BY RELIEVING PRESSURE BEFORE DICONNECTING
HYDRAULIC LINES.
ENSURE ALL CONNECTIONS ARE TIGHT BEFORE APPLYING
PRESSURE, SEARCH FOR LEAKS WITH A PIECE OF CARDBOARD
NOT YOUR HANDS!
IMPROPER HOOK-UP CAN CAUSE DANGEROUS BOOM
MOVEMENTS AND/OR DAMAGE TO THE SPRAYER HYDRAULICS.
DO NOT ALLOW ANYONE NEAR A HYDRAULIC BOOM IN
OPERATION.
ALWAYS SHUT TRACTOR OFF WHEN CONNECTING, SERVICING
OR ADJUSTING BOOM.
1. Attach the heavier (3/8") hydraulic hose for the boom lift to the tractor's
single acting outlet.
2. Attach the lighter (1/4") hydraulic hoses for boom folding & HZ tilt to
the tractor's double acting outlet.