17
HARDI
MEGA 230 / 350 CENTRIFUGAL OPERATORS MANUAL
Fig.6
A
4.4 Mounting Hydraulic Hoses (cont'd)
4. Disconnect fold cylinder rod (adjustable eye end) from wing section.
5. Ensure cylinder is free of obstruction for retraction and extension.
6. Connect hydraulic hoses to double acting outlet on tractor. (Refer to
section 11 for hydraulic schematics)
7. Start tractor engine and cycle fold cylinders by actuating double
acting outlet 10 times to bleed air from hydraulic system.
8. Stop tractor engine, check hydraulic reservoir oil level and fill as
necessary.
9. Attach fold cylinder rods to boom sections, using previously re-
moved pins and cotter pins.
B/ TILT CYLINDERS
1. If hydraulic tilt cylinders are fitted to the spray boom, air should be
bled from these lines before spraying.
2. Disconnect tilt cylinder rod eyes from wing section.