18
HARDI
MEGA 230 / 350 CENTRIFUGAL OPERATORS MANUAL
4.4 Mounting Hydraulic Hoses (cont'd)
Fig. 7
CAUTION! Wing section must be supported before removal of
hydraulic cylinder rod eyes.
3. Ensure cylinder is free of obstruction for retraction and extension.
4. Start tractor engine and cycle tilt cylinder by actuating double acting
outlet 10 times to bleed air from hydraulic cylinders.
5. Stop tractor engine, check hydraulic reservoir oil level and fill as
necessary.
6. Reattach tilt cylinder rods to boom sections.
4.5 Installing Center Frame Spray Tube Assembly
1. Attach brackets to center frame using M6x30mm cap screws and lock
nuts.
NOTE: To gain access to mounting holes on the nozzle track,
remove plastic nozzle retaining nuts closest to mount holes
and remove tube as necessary to install cap screws from
the bottom.
2. Attach spray tube assembly using M6x20mm cap screws with lock
nuts on top. The 4 nozzle tube is to be on the right-hand side.