7 - Menu 3 Calibration
39
Menu 3.2 Flow calibration
Which method to use
The flow transducer can be calibrated theoretically or with two practical
methods. The practical methods are preferred. Calibration is done with
clean water. The Flow Tank method is time consuming, but is more
accurate than the Flow Nozzle method.
When changing to nozzles with more than a 100% increase or decrease
in output, it is recommended to recalibrate the flow transducer.
Calibration is recommended to be done at least once during the
spraying season. Use the chart at the back of the book to record the
values.
Menu 3.2.1 Flow constant
Use the navigation keys to change the flow constant theoretically.
Approximate PPU values for different flow housings are as follows in the
table. Different flow housings are designated by groove (A).
μ
ATTENTION! PPU indicates the number of pulses which theoretically come from the flow transducer whilst 1 litre of
liquid passes through.
Housing
Housing identification (A)
Flow range
L/min.
Orifice
mm
PPU
value
S/67 Three
grooves
1-30
6
310.00
S/67
Four grooves
2.5-75
9.5
180.00
S/67
One outside groove
5 -150
13.5
120.00
S/67
No groove
10-300
20.0
60.00
S/67
Two outside grooves
35 - 600
36.0
17.00
Pressure drop over 13.5 mm orifice is 1 bar at 150 l/min.
CALIBRATION
Flow calibration
3.2
SPRAYER
Practical
3.2.1
Summary of Contents for HC5500
Page 6: ...Table of Contents 6 ...
Page 8: ...1 CE Declaration 8 ...
Page 10: ...2 Safety notes 10 ...
Page 26: ...4 System setup 26 ...
Page 30: ...5 Menu 1 Daily settings 30 ...
Page 60: ...8 Menu 4 Toolbox 60 ...
Page 66: ...11 Maintenance 66 ...
Page 76: ...14 Technical specifications 76 ...
Page 78: ...Index 78 ...
Page 80: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...