7 - Menu 3 Calibration
52
If custom nozzle LookAhead calibration is selected the flow at 3 bars
must first be defined.
1.
Enter value.
2.
Confirm by pressing
.
3.
Do all the above calibration routine as usual.
μ
ATTENTION! To calibrate, the speed must exceed the minimum speed set in the controller memory. If minimum
driving speed is set too high, please contact your local HARDI dealer.
μ
ATTENTION! If all section valves are turned off then LookAhead is standby. When turning single sections off, e.g. in
wedge shaped fields, then last valve must be turned off by using the main on/off.
μ
ATTENTION! During the entire calibration process the fluid system should be in “Auto” mode. If not, press ® to enable it.
μ
ATTENTION! When using very large nozzles it could be necessary to reduce speed until application rate is stable.
μ
ATTENTION! If controller suggest a speed lower than min. regulation speed, then choose a higher application rate.
CUSTOM 1
X.XX l/min
3.7.XX.X