Page 6
For technical questions, please call 1-888-866-5797.
Item 63785
Connect Cables
Ground Clamp Cable
in Positive Socket
Ground
Clamp
TIG Torch
Cable in
Negative
Socket
TIG Torch
Foot Pedal Socket
(inside Welder)
Foot Pedal
(sold separately)
Foot Pedal
Cable
1.
OMNIPRO 220:
a. Plug TIG Torch Cable into Torch Adapter. Twist
clockwise all the way to lock into place.
b. Plug Torch Adapter into Negative Socket.
Twist clockwise all the way to lock in place.
c. Insert the Foot Pedal Cable, through hole
on Welder front and connect to the Foot
Pedal Socket inside the machine. Secure
by turning collar clockwise until tight.
d. Plug Ground Clamp cable into Positive Socket.
Twist clockwise all the way to lock in place.
2.
PROTIG 165 and 200:
a. Plug Ground Clamp cable into Positive Socket.
Twist clockwise all the way to lock in place.
b. Plug TIG Torch cable into Negative Socket.
Twist clockwise all the way to lock in place.
c. Plug Foot Pedal cable into Foot Pedal Socket.
Secure by turning collar clockwise until tight.
OMNIPRO 220
Torch
Adapter