Page 8
For technical questions, please call 1-888-866-5797.
Item 63785
Connect Shielding Gas
1.
With assistance, place an 100% Argon cylinder
(not included) onto a cabinet or cart near the
Welder and secure the cylinder in place with
two straps (not included) to prevent tipping.
2. Remove the cylinder’s cap. Stand to the
side of the valve opening, then open the
valve briefly to blow dust and dirt from the
valve opening. Close the cylinder valve.
3. Locate the Regulator (included) and close its
valve until it is loose, then thread Regulator
onto cylinder and wrench-tighten connection.
4. Connect Gas Hose.
a.
OMNIPRO 220:
Connect Shielding Gas
Hose on TIG Torch Cable Connector to the
Regulator’s Outlet and wrench-tighten connection.
b.
PROTIG 165 and 200:
Attach the Gas Hose to
the Regulator’s Outlet and the Welder’s Gas Inlet.
Wrench-tighten both connections.
5. Open Gas Flow Valve on Torch.
Note:
When using TIG Torch with OMNIPRO 220,
gas flow is continuous. Close Gas Flow Valve
on TIG Torch when welding is complete.
4 a
3
1
Briefly open valve
to clean,
then close
valve.
2
4b
Power Input
Gas Inlet
Reset
Power Input
Gas Inlet
4b
PROTIG 165
PROTIG 200
5
Gas Flow
Valve