INITIAL INSTALLATION

 

Install ball end of motor assembly (D) into 
mounting bracket (B) opening. Align slot in ball 
with tab in mounting bracket (A). (Fig. 5)

       

DANGER:

 Failure to align slot in ball with tab 

in mounting bracket (B) may result in serious 
injury or death. (Fig. 5)

Q

M

5

 5. 

To ensure the safety of the installation and to 
prevent the motor assembly (D) from becoming or 
coming loose, use the plastic lock tab (C). Slide 
plastic lock tab (C) 

under

 bracket tabs so that it will 

snap into place. (Fig. 6)
 

IMPORTANT: Keep in mind that it will require 
some force to fully insert the plastic lock tab (C) 
so that it does not move or come out once in 
the correct position.

NOTE:

 Make sure that motor assembly (D) does 

not swing from side to side too easily--

if it does, 

check to be sure that the plastic lock tab (C) is 
FULLY INSERTED under the bracket tabs and all 
the way to the back of the mounting bracket (B).

6

 6. 

Wood 

Screw

Screw

Loop

Nut

7

B

Adjust safety cable (M) length by loosening screw 
and nut on the safety cable vice (Q) and pulling on 
the safety cable (M). Adjust slack in cable to a hands 
length and tighten screw and nut on vice (Q) 
securely. The loop at the end of the safety cable (M) 
should just fit over the threads on the wood screw. 
(Fig. 7) 

Test safety cable (M) by pulling on loose end 

with pliers. If the safety cable (M) slips, then vice (Q) 
screw and nut must be set tighter.

 7. 

Hanging

Tab

Ball

Slot

B

D

Bracket

Tab

 C

B

D

Summary of Contents for CHESHIRE II

Page 1: ...arts Before returning to your retailer call our customer service department at 1 800 527 1292 8 30 a m 5 p m CST Monday Friday Federal regulations require ceiling fans with light kits manufactured or...

Page 2: ...on or foam inserts Should this fan need to be returned to the factory for repairs it must be shipped in its original packaging to ensure proper protection against damage that might exceed the initial...

Page 3: ...arp edges To reduce the risk of fire electrical shock or personal injury wire connectors provided with this fan are designed to accept only one 12 gauge house wire and two lead wires from the fan If y...

Page 4: ...Motor Housing Mounting 4 Screw preassembled O Motor Screw 10 preassembled P 5 4 M M Lock Washer 10 preassembled Q Vice preassembled 1 PART DESCRIPTION QUANTITY A Motor Housing 1 B Mounting Bracket 1...

Page 5: ...self Wiring Handbook available at Lowe s and Wire Cutters Bulbs Required included 3 candelabra base 60 watt max bulbs DANGER When using an existing outlet box make sure the outlet box is securely atta...

Page 6: ...unting bracket B to outlet box using screws spring washers and flat washers provided with the outlet box Fig 3 Pull wires from outlet box through center hole in mounting bracket B Note It is very impo...

Page 7: ...not move or come out once in the correct position NOTE Make sure that motor assembly D does not swing from side to side too easily if it does check to be sure that the plastic lock tab C is FULLY INS...

Page 8: ...HITE wire from ceiling Connect GROUND GREEN wire from mounting bracket to BARE GREEN wire from ceiling Fig 1A 1 FAN AND LIGHT CONTROLLED BY PULL CHAINS BLACK WHITE GROUND GREEN BARE WHITE BLUE WHITE F...

Page 9: ...s on opposite side of box from the black and blue if applicable connections Turn spliced taped wires upward and gently push wires and wire connectors CC into outlet box CC CC 2 CC CC E3 Wire Connector...

Page 10: ...osen these two motor housing mounting screws N Remove the other two motor housing mounting screws N Now lift motor housing A to mounting bracket B again aligning slotted holes in motor housing A with...

Page 11: ...ing Plate If you wish to USE the light kit remove three screws from switch housing plate on underside of motor Locate BLUE or BLACK and WHITE wires in switch housing plate labeled FOR LIGHT and remove...

Page 12: ...6 The pull chain extensions J supplied in one of the hardware packs or custom pull chain extensions sold separately may be attached to fan and light pull chains Fig 8 Install three candelabra base 60...

Page 13: ...h on the switch housing plate for the proper fit Re insert screws that were previously removed Use a Phillips screwdriver to secure all screws Fig 2 Switch Housing Plate L Switch Housing Plate A 3 3 T...

Page 14: ...ur comfort Note Wait for fan to stop before moving the reverse switch 3 E 3A In warmer weather setting the reverse switch in the LEFT position will result in downward airflow creating a wind chill eff...

Page 15: ...n power off Loosen motor housing A and check all connections Noisy operation 1 Blades H are loose 1 Tighten all blade screws AA 2 Cracked blade H 2 Replace blade H 3 Full range dimmer switch 3 Replace...

Page 16: ...e warranty Any replacement of defective parts for the ceiling fan must be reported within the first year from the date of purchase For the balance of the warranty call our customer service department...

Page 17: ...Ring L Extra Switch Housing N Motor Housing Mounting Screw O Motor Screw P 5 4M M Lock Washer AA Blade Screw BB Fiber Blade Washer CC E3 Wire Connector For replacement parts call our customer service...

Reviews: