background image

11

FINAL INSTALLATION

Fan Pull Chain Slot

and Pull Chain

Locate motor screws (O) and 5.4 M/M lock washers 
(P) that were removed in Step 4 on page 6. 

Insert two motor screws (O), along with 5.4 M/M lock 
washers (P), through one blade arm (G) to attach 
blade arm (G) to motor. Tighten motor screws (O) 
securely. (Fig. 3) Repeat with remaining blade arms 
(G), making sure to completely secure each blade 
arm (G) before proceeding with the next.

Note: 

For easy access to motor screws (O), turn 

switch housing plate so that the flat part of the switch 
housing plate aligns with the two motor screws (O) 
on blade arm (G).

Repeat Step 3 with remaining blade arms (G), 
making sure to completely secure each blade arm 
(G) before proceeding with the next.

3

3. 

A

G

H

O

 P

Switch 

Housing

Plate

If you wish to USE the light kit

, remove three 

screws from switch housing plate on underside of 
motor. Locate 

BLUE

 (or 

BLACK

) and 

WHITE

 wires 

in switch housing plate labeled FOR LIGHT and 
remove plastic from these two wires. 

Connect 

WHITE

 wire from light kit fitter (E) to 

WHITE

 wire from switch housing plate. Connect 

BLACK

 wire from light kit fitter (E) to 

BLUE

 (or 

BLACK

) wire from switch housing plate. Make sure 

that molex connections are secure. (Fig. 4) 
Continue with Step 5. 

If you do NOT wish to use the light kit,

 please go 

to section entitled “Installing Fan Without Included 
Light Kit” on page 13.

4

4.

Switch 

Housing

Plate

Molex

Connections

A

E

Arrange wires and molex connections in switch 
housing plate. Align fan pull chain slot with fan pull 
chain and attach light kit fitter (E) to fan with screws 
that were removed in the previous step. Use a Phillips 
screwdriver to secure all three screws. (Fig. 5)

5

5.

A

E

Switch 

Housing

Plate

Summary of Contents for CHESHIRE II

Page 1: ...arts Before returning to your retailer call our customer service department at 1 800 527 1292 8 30 a m 5 p m CST Monday Friday Federal regulations require ceiling fans with light kits manufactured or...

Page 2: ...on or foam inserts Should this fan need to be returned to the factory for repairs it must be shipped in its original packaging to ensure proper protection against damage that might exceed the initial...

Page 3: ...arp edges To reduce the risk of fire electrical shock or personal injury wire connectors provided with this fan are designed to accept only one 12 gauge house wire and two lead wires from the fan If y...

Page 4: ...Motor Housing Mounting 4 Screw preassembled O Motor Screw 10 preassembled P 5 4 M M Lock Washer 10 preassembled Q Vice preassembled 1 PART DESCRIPTION QUANTITY A Motor Housing 1 B Mounting Bracket 1...

Page 5: ...self Wiring Handbook available at Lowe s and Wire Cutters Bulbs Required included 3 candelabra base 60 watt max bulbs DANGER When using an existing outlet box make sure the outlet box is securely atta...

Page 6: ...unting bracket B to outlet box using screws spring washers and flat washers provided with the outlet box Fig 3 Pull wires from outlet box through center hole in mounting bracket B Note It is very impo...

Page 7: ...not move or come out once in the correct position NOTE Make sure that motor assembly D does not swing from side to side too easily if it does check to be sure that the plastic lock tab C is FULLY INS...

Page 8: ...HITE wire from ceiling Connect GROUND GREEN wire from mounting bracket to BARE GREEN wire from ceiling Fig 1A 1 FAN AND LIGHT CONTROLLED BY PULL CHAINS BLACK WHITE GROUND GREEN BARE WHITE BLUE WHITE F...

Page 9: ...s on opposite side of box from the black and blue if applicable connections Turn spliced taped wires upward and gently push wires and wire connectors CC into outlet box CC CC 2 CC CC E3 Wire Connector...

Page 10: ...osen these two motor housing mounting screws N Remove the other two motor housing mounting screws N Now lift motor housing A to mounting bracket B again aligning slotted holes in motor housing A with...

Page 11: ...ing Plate If you wish to USE the light kit remove three screws from switch housing plate on underside of motor Locate BLUE or BLACK and WHITE wires in switch housing plate labeled FOR LIGHT and remove...

Page 12: ...6 The pull chain extensions J supplied in one of the hardware packs or custom pull chain extensions sold separately may be attached to fan and light pull chains Fig 8 Install three candelabra base 60...

Page 13: ...h on the switch housing plate for the proper fit Re insert screws that were previously removed Use a Phillips screwdriver to secure all screws Fig 2 Switch Housing Plate L Switch Housing Plate A 3 3 T...

Page 14: ...ur comfort Note Wait for fan to stop before moving the reverse switch 3 E 3A In warmer weather setting the reverse switch in the LEFT position will result in downward airflow creating a wind chill eff...

Page 15: ...n power off Loosen motor housing A and check all connections Noisy operation 1 Blades H are loose 1 Tighten all blade screws AA 2 Cracked blade H 2 Replace blade H 3 Full range dimmer switch 3 Replace...

Page 16: ...e warranty Any replacement of defective parts for the ceiling fan must be reported within the first year from the date of purchase For the balance of the warranty call our customer service department...

Page 17: ...Ring L Extra Switch Housing N Motor Housing Mounting Screw O Motor Screw P 5 4M M Lock Washer AA Blade Screw BB Fiber Blade Washer CC E3 Wire Connector For replacement parts call our customer service...