4.
Depending on the length of downrod (A) you use, you
may need to cut the lead wires back to simplify the wiring.
If you decide to cut back the lead wires, it is suggested
that you do so in the following manner:
Take the lead wires and make sure that you have pulled
them all the way through the top of the downrod (A). Start
at the TOP of the ball on the downrod (A) and measure 8
in. of lead wire, and then cut the excess wire off with wire
cutters. (Fig. 4)
Note:
If you did
not
cut back the lead wires,
Steps 4 and
5 are not necessary and you may proceed to Step 6
instead
.
6.
Install ball end of downrod (A) into mounting
bracket (C) opening. Align slot in ball with tab in
mounting bracket (C). (Fig. 6)
DANGER:
Failure to align slot in ball with
tab may result in serious injury or death.
Continue to "Wiring" instructions on page 10.
Fig. 6
Hanging
Ball Slot
1
. Remove canopy cover (O) from bottom of canopy (B).
(Fig. 1) [Note: It may be necessary to use the handle end of
a screwdriver to remove the canopy cover (O) by tapping
on the canopy cover (O) from the inside of the canopy (B).]
*Helpful Hint:
Close style mounting is more suitable for
ceilings lower than 8 ft. (2.44 m) high. The downrod (A),
hanging ball, yoke cover (D), and canopy cover (O) are not
used in this type of installation.
Fig. 1
CLOSEMOUNT STYLE FAN MOUNTING
A
B
C
B
O
Tab
Ball
DOWNROD STYLE FAN MOUNTING
9
5.
If you decided to cut back the lead wires in Step 4, strip
1/2 of an inch of insulation from end of white wire. Twist
stripped ends of each strand of wire within the insulation
with pliers. (Fig. 5) Repeat Step 5 for black, blue (if
applicable) and green wires.
Fig. 5
Fig. 4
Ball
A
E