19
WARNING
: Before beginning work, shut off the power supply to avoid electrical shock.
TROUBLESHOOTING
Excessive
wobbling.
1. Re-install bulb(s).
2. Check wires in canopy and, if
necessary, re-wire according to
instructions on pages 11 and 12.
3. Make sure wall switch to light is on.
4. Check molex connections in light
kit fitter and ensure they are
connected properly according to
instructions on page 14.
1. Bulb(s) not installed correctly.
2. Wires in canopy not wired
properly.
3. Wall switch to light is off.
4. Wires in light kit fitter not wired
correctly.
Fan operates but
light fails (if
applicable).
NOTE:
A small amount of "wobble" is normal and should not be considered a defect.
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
Fan does not
move.
Noisy operation.
1. Blades are loose.
2. Cracked blade.
3. Full range dimmer switch.
4. Fan is new.
1. Tighten all blade screws.
2. Replace blade.
3. Replace with an approved speed
control device.
4. Allow fan a “break in” period of a
few days, especially when running
the fan at Medium and High
speeds.
1. Blades are loose.
2. Blade arms incorrectly attached.
3. Unbalanced blades.
4. Fan not securely mounted.
5. Fan too close to vaulted ceiling.
6. Set screw(s) on motor housing yoke
is (are) not tightened properly.
1. Tighten all blade screws.
2. Re-install blade arms.
3. Switch one blade with a blade
from the opposite side or use
balancing kit (R).
4. Turn power off. Carefully loosen
canopy and verify mounting
bracket is secure.
5. Use a longer downrod or move
fan to another location.
6. Tighten yoke set screw(s)
securely.
1. Reverse switch not engaged.
2. Power is off or fuse is blown.
3. Faulty wire connection.
4. Plugs not connected properly.
1. Push switch firmly either left or
right.
2. Turn power on or check fuse.
3. Turn power off. Loosen canopy
and check all connections.
4. Check male and female plugs
in switch housing are connected
properly according to instructions