5.2.3 Pattern repeat/Link setting
Time Signal
T/S 1
T/S 2
T/S 7
T/S 8
Description
At the start point of segment 1, time signal becomes ON and after elapsing 2 hours, it will become OFF.
(ON Delay : 00 h 00 m), (ON Time : 02 h 00 m)
At the start point of segment 6, time signal becomes ON and after elapsing 2 hours, it will become OFF.
(Since segment 6 is 2 hours, it only yield the output for 2 hours even if On Time is set as 3 hours)
(ON Delay : 00 h 00 m), (ON Time : 03 h 00 m)
At the start point of segment 1, time signal becomes ON after delaying 30 minutes
and becomes OFF after elapsing 2hour30minutes.
(ON Delay : 00 h 30 m), (ON Time : 02 h 30 m)
At the start point of segment 6, time signal becomes ON after delaying 30 minutes and
becomes OFF after elapsing 1hour
(ON Delay : 00 h 30 m), (ON Time : 01 h 00 m)
At the start point of segment 3, time signal becomes ON and after elapsing 4 hours, it will become OFF.
(ON Delay : 00 h 00 m), (ON Time : 04 h 00 m)
Time signal becomes ON in each of segment 2, 4 and 6 and after elapsing ON
time, it will become OFF.
Time Signal will be OFF once the program ends regardless of setting modes.
Pressing
button in [Fig.44] Function
Setting menu screen, and pressing
button
in [Fig.45], Pattern REPEAT/LINK setup [Fig.55] is
shown. If you set Current Pattern repeat count to
Pattern repeat on the right side of the top and
Current Pattern number to connect Pattern,
Current pattern will be run in unlimited repeat
according to Segment Operation.
Program operation executes inputted segment in
sequence basically, but it comes occasionally that the
[Fig.55] Pattern repeat/Connect setting screen
case of set segment contents in pattern should be repeated & executed. Using Section repeat in
that time, reduce Program input as much as possible.You can move among Section repeat setting
pages by using the
/ arrow buttons on the right side in the order ranging from 1 to 20 in
total.