installation & connection
18_
installation & connection
Connecting to the I/O device
Connect the Alarm I/O cable to the corresponding port of the port box.
Sensor
Alarm
(Warning lamp)
~
ALARM 1~4 : These ports can be used as alarm input or output ports. If used as input ports, alarm input
or day/night sensors can be connect to them. If used as output ports, alarm output signals
can be connect to them.
※
The setting of each alarm input/output port can be changed at the Web Viewer setting
menu.
~
GND : Common ground for alarm in/output signal.
J
`
If devices (e.g., flashing light and siren) that exceed the voltage and current specifications are connected by using the open
collector method, it may cause malfunction.
Refer to the “
Alarm Out Wiring Diagram
” when connecting devices such as a warning lamp or a siren.
Sensor
GND
RESISTOR
ALARM IN (5mA SINK)
RESISTOR
RESISTOR
VCC_3.3V
DIODE
GND
MLCC
TRANSISTOR
External
connection
Inside of the camera
Warning lamp /
Siren power
Warning lamp /
Siren
ALARM OUT (12VDC 20mA MAX)
RESISTOR
10K ohm
DIODE
RELAY
DC 5V or 3.3V
TRANSISTOR
GND
GND
TRANSISTOR
External connection
Inside of the camera
GND
RESISTOR
Connecting to an external sensor
One of the signal lines (2 wires) of various sensors is connected to the [
ALARM 1~4
(where the
corresponding terminal is set as input)] terminal, and the other connected to the [
GND
] terminal.
Alarm In Wiring Diagram
Alarm Out Wiring Diagram