2. Safety 
 

2.1 Introduction 

The safety alert symbol identifies important safety messages on your PipeFeeder and in 
the manual. When you see this symbol, be alert to the possibility of personal injury or 
death. Follow the instruction of the safety message. 
 
 

 
 
 
 
 

Safety Alert Symbol 

2.2 Signal Words 
 

Note the use of the signal words DANGER, WARNING and CAUTION with the safety mes-
sages. The signal word for each message uses the following guidelines: 

 

Warning! 

Indicates a potentially hazardous situation that, if not avoided, could re-

sult in death or serious injury, and includes hazards that are exposed when guards 

are removed. 

Danger! 

Indicates a imminently hazardous situation that, if not avoided, will re-sult 

in death or serious injury. 
 

2.3 Safety Instructions 
 

YOU are responsible for the SAFE operation and maintenance of your PipeFeeder. YOU 
must make sure that you and anyone else who is going to operate, maintain or work in 
the vicinity of the PipeFeeder knows all the related SAFETY information in this manual. 
 
YOU are the key to safety. Good safety practices protect you and the people around you. 
Make these practices a working part of your safety program. Make sure EVERYONE who 
operates, maintains or works near the PipeFeeder obeys the safety precautions. Do not 
risk injury or death by ignoring good safety practices. 
 

 

PipeFeeder owners must train operators before they operate the PipeFeeder. This 
training must be repeated at least annually. 

 

The operator must read, understand and obey all safety and operating instructions 
in the manual. 

 

 A person who has not read and understood all safety and operatinginstructions is 
not permitted to operate the PipeFeeder. 

 

Do not modify the equipment in any way. Unauthorized modification may impair 
the function and/or safety and could affect the life of the equipment, and persons. 

 

 Only use approved spare parts, and make sure they are only installed by authori-
zed technicians. 

Summary of Contents for PipeFeeder

Page 1: ...truction Article number 1847 Datum August 2014 Version 2 2 Translation of Original Instructions for use According to Annex 1 Chapter 1 7 4 Machine guideline 2006 42 EG Zelhem The Netherlands www hansk...

Page 2: ...faults in this manual The recommendations are meant to serve as guidelines All instructions pictures and specifications in this manual are based on the latest information that was available at the tim...

Page 3: ...vative PipeFeeder concentrate feeding system from Hanskamp which ensures pellets are fed precisely and silently The PipeFeeder features an ingenious anti spill system also developed by Hanskamp On ce...

Page 4: ...of your PipeFeeder YOU must make sure that you and anyone else who is going to operate maintain or work in the vicinity of the PipeFeeder knows all the related SAFETY information in this manual YOU a...

Page 5: ...of the electrical system and all parts of the PipeFeeder meet the local rules and regulations Replace any damaged electrical lines conduits switches and components imme diately Isolate the electrical...

Page 6: ...electrical power supply by taking plug out of the power point and secure the plug before you clean or do maintenance on the PipeFeeder Wear protective clothing and safety goggles when you do work on t...

Page 7: ...nskamp please consult the instal lation instruction no 1840 for connecting and adjusting the PCB See the annex for the order numbers and names of the various parts Transport and storage The PipeFeeder...

Page 8: ...ht position for the sticker Remove a small portion of the foil on the back Place the sticker on the surface and press a small portion of the self adhesive layer onto the surface Carefully remove the f...

Page 9: ...PipeFeeder This way air can run underneath the PipeFeeder 4 Use a well shielded electricity cable to connect the dosing unit See the annex on page 15 for the connection diagram for the various motors...

Page 10: ...milking stall feeding installation in parlour and in the feeding box out of parlour 8 When installation is not completely correct the plastic part will be able to rotate freely with respect to the sta...

Page 11: ...eeder cannot start unexpectedly Make sure there is no voltage on the installation To do this plug the power supply off at the control unit of the dosing motor 3 It is recommended to have repairs and m...

Page 12: ...nformation given in this publication is provided for information purposes only and does not constitute an offer for sale The products supplied may differ from those illustrated No part of this publica...

Page 13: ...fully complies with the provisions of the following di rective s Machine Directive 2006 42 EC and completely or partially meets the following essential requirements and that the rele vant technical do...

Page 14: ...ece between the motor and drive shaft could be broken Remove motor of rotor and reinsert note settings for anti spill pag 10 step 7 Constipation by for example wood or plastic Remove the PipeFeeder of...

Page 15: ...24VDC 28 rpm Anti spill Solid State 5 DV 7 1663 24VDC 28 rpm OV 8 1001 24VDC 41 rpm Anti spill DV Example Art No 27321 A 1500mm normal blue PipeFeeder with SolidState motor HighSpeed version always m...

Page 16: ...anskamp nl en Pipefeeder EN 24VAC 12 24VDC Loose components It is possible to reorder loose components from your supplier for maintenance or for any other reason Please use the item numbers shown belo...

Page 17: ...94 Bottom plate AC 1 1895 Angled safety plate 1 1896 Bottom plate DC HighSpeed 1 1899 Sheet section of sealed compartment 1 1902 Wall mounting bracket 129 complete 2 1903 MDPE plastic T piece 45 with...

Page 18: ...18 20 Hanskamp AgroTech B V the Netherlands www hanskamp nl en Pipefeeder EN 24VAC 12 24VDC Installation dimensions Visit us on 10...

Page 19: ...19 20 Hanskamp AgroTech B V the Netherlands www hanskamp nl en Pipefeeder EN 24VAC 12 24VDC...

Page 20: ...20 Hanskamp AgroTech B V the Netherlands www hanskamp nl en Pipefeeder EN 24VAC 12 24VDC Hanskamp Arendsenweg 7 7021 PC Zelhem The Netherlands Tel 31 0 314 393 797 Fax 31 0 314 393 826 www hanskamp n...

Reviews: