2.3.1 General Safety 

 

 

Read and understand the manual and all safety signs before you connect power 
supplies to operate, maintain or adjust the PipeFeeder.  

 

Only trained persons are permitted to operate the PipeFeeder. A first-aid kit must 
be available near the PipeFeeder. Store in a highly visible place. 

 

A carbon dioxide or foam fire extinguisher must be available near the PipeFeeder. 
Store the fire extinguisher in a highly visible place. 

 

Install all protective covers and guards before you operate the PipeFeeder. 

 

Wear the correct protective clothing and equipment. Disconnect and isolate the 
electrical power supply before you clean or do maintenance on the PipeFeeder, 
also be sure that the compressed air supply is depressurised.  

 

Know the emergency medical centre number for your area. 

 

Contact your nearest milking equipment dealer provider if you have any questi-
ons 

 

Review safety related items with all operators frequently (annually).  

 

2.3.2 Electrical Safety

 

 

Only an authorized electrician must install the electrical power supply for the 
PipeFeeder. 

 

Make sure the electrical grounding of the electrical system and all parts of the 
PipeFeeder meet the local rules and regulations. 

 

Replace any damaged electrical lines, conduits, switches and components imme-
diately. 

 

Isolate the electrical power supply before you open the lid of the PipeFeeder to 
work on the electrical system.  

 

2.3.3 Installation Safety 

 

 

 Read and understand the instructions in this manual. 

 

Make sure the PipeFeeder is correctly installed.  

 

2.3.4 Operating Safety 

 

 

Read and understand the applicable manual and all safety signs before you con-
nect power supplies to operate, maintain or adjust the PipeFeeder. 

 

Only trained persons are permitted to operate the PipeFeeder. 

 

Switch off the electrical power supply by taking plug out of the power point and 
secure the plug before you clean or do maintenance on the PipeFeeder. Be sure 
that the compressed air supply is depressurised, switch the compressor of by 
using the main switch of the compressor, and close the air valve. 

 

Install the covers and guards before you operate the PipeFeeder. 

 

Keep hands, feet, hair and clothing away from all the electrical parts. 

 

Keep unauthorized persons, especially small children away from the PipeFeeder 
at all times. 

 

Before the electrical supply is attached to the PipeFeeder, make sure all parts are 
tight and that all the parts are in good condition. 

 

Contact your nearest milking equipment dealer if you have any questions.  

 
 

Summary of Contents for PipeFeeder

Page 1: ...truction Article number 1847 Datum August 2014 Version 2 2 Translation of Original Instructions for use According to Annex 1 Chapter 1 7 4 Machine guideline 2006 42 EG Zelhem The Netherlands www hansk...

Page 2: ...faults in this manual The recommendations are meant to serve as guidelines All instructions pictures and specifications in this manual are based on the latest information that was available at the tim...

Page 3: ...vative PipeFeeder concentrate feeding system from Hanskamp which ensures pellets are fed precisely and silently The PipeFeeder features an ingenious anti spill system also developed by Hanskamp On ce...

Page 4: ...of your PipeFeeder YOU must make sure that you and anyone else who is going to operate maintain or work in the vicinity of the PipeFeeder knows all the related SAFETY information in this manual YOU a...

Page 5: ...of the electrical system and all parts of the PipeFeeder meet the local rules and regulations Replace any damaged electrical lines conduits switches and components imme diately Isolate the electrical...

Page 6: ...electrical power supply by taking plug out of the power point and secure the plug before you clean or do maintenance on the PipeFeeder Wear protective clothing and safety goggles when you do work on t...

Page 7: ...nskamp please consult the instal lation instruction no 1840 for connecting and adjusting the PCB See the annex for the order numbers and names of the various parts Transport and storage The PipeFeeder...

Page 8: ...ht position for the sticker Remove a small portion of the foil on the back Place the sticker on the surface and press a small portion of the self adhesive layer onto the surface Carefully remove the f...

Page 9: ...PipeFeeder This way air can run underneath the PipeFeeder 4 Use a well shielded electricity cable to connect the dosing unit See the annex on page 15 for the connection diagram for the various motors...

Page 10: ...milking stall feeding installation in parlour and in the feeding box out of parlour 8 When installation is not completely correct the plastic part will be able to rotate freely with respect to the sta...

Page 11: ...eeder cannot start unexpectedly Make sure there is no voltage on the installation To do this plug the power supply off at the control unit of the dosing motor 3 It is recommended to have repairs and m...

Page 12: ...nformation given in this publication is provided for information purposes only and does not constitute an offer for sale The products supplied may differ from those illustrated No part of this publica...

Page 13: ...fully complies with the provisions of the following di rective s Machine Directive 2006 42 EC and completely or partially meets the following essential requirements and that the rele vant technical do...

Page 14: ...ece between the motor and drive shaft could be broken Remove motor of rotor and reinsert note settings for anti spill pag 10 step 7 Constipation by for example wood or plastic Remove the PipeFeeder of...

Page 15: ...24VDC 28 rpm Anti spill Solid State 5 DV 7 1663 24VDC 28 rpm OV 8 1001 24VDC 41 rpm Anti spill DV Example Art No 27321 A 1500mm normal blue PipeFeeder with SolidState motor HighSpeed version always m...

Page 16: ...anskamp nl en Pipefeeder EN 24VAC 12 24VDC Loose components It is possible to reorder loose components from your supplier for maintenance or for any other reason Please use the item numbers shown belo...

Page 17: ...94 Bottom plate AC 1 1895 Angled safety plate 1 1896 Bottom plate DC HighSpeed 1 1899 Sheet section of sealed compartment 1 1902 Wall mounting bracket 129 complete 2 1903 MDPE plastic T piece 45 with...

Page 18: ...18 20 Hanskamp AgroTech B V the Netherlands www hanskamp nl en Pipefeeder EN 24VAC 12 24VDC Installation dimensions Visit us on 10...

Page 19: ...19 20 Hanskamp AgroTech B V the Netherlands www hanskamp nl en Pipefeeder EN 24VAC 12 24VDC...

Page 20: ...20 Hanskamp AgroTech B V the Netherlands www hanskamp nl en Pipefeeder EN 24VAC 12 24VDC Hanskamp Arendsenweg 7 7021 PC Zelhem The Netherlands Tel 31 0 314 393 797 Fax 31 0 314 393 826 www hanskamp n...

Reviews: