Materials required for assembly

Page 15

(5)

4. Fit the activated carbon filters (5) to the 

right and left of the motor as illustrated 
and tighten them by turning them anti-
clockwise, allowing the locks to click into-
place.

(8)

5. Insert the  grease filter (8) by placing the 

back end in the recess on the exhaust 
hood. Slide the lock backwards, hinge the 
grease filter (8) downwards to close it, 
and release the lock again.

6. Reconnect the power supply.
7. Press the button (13)  to switch the ap-

pliance on and off for another 3 seconds. 
The exhaust hood’s will close.

Summary of Contents for 53906622

Page 1: ...Gebrauchsanleitung Anleitung Version 196635_20180724_DE Bestell Nr 53906622 Nachdruck auch auszugs weise nicht gestattet SY 103D1 E3 C25 900 Unterbau Dunstabzugshaube...

Page 2: ...altverz gerung 17 Betriebsleuchte 17 Pflege und Wartung 18 Geh use reinigen 18 Fettfilter reinigen 18 Aktivkohlefilter einsetzen ersetzen 19 Beleuchtung 20 Fehlersuchtabelle 21 Unser Service 22 Allgem...

Page 3: ...zum Lieferumfang geh ren diezurWandmontageben tigtenSchrauben und D bel da deren Art und Abmessungen von der Wandbeschaffenheit abh ngig sind Bitte lassen Sie sich hierzu im Fachhandel beraten siehe...

Page 4: ...it einem niedrigen Risiko grad die wenn sie nicht vermieden wird eine geringf gige oder m ige Verletzung zur Folge haben kann HINWEIS Dieser Signalbegriff warnt vor m gli chen Sachsch den Dieses Symbo...

Page 5: ...Fachkraft ausgetauscht werden Eingriffe und Reparaturen am Ger t d rfen ausschlie lich autorisierte Fachkr fte vornehmen Bei Reparaturen d rfen ausschlie lich Teile verwendet werden die den urspr ngl...

Page 6: ...urch Kinder durchgef hrt werden es sei denn sie werden beaufsichtigt Kinder d rfen nicht mit dem Ger t spielen Verletzungsgefahr Bei der Montage beachten dass eini ge Teile scharfe Kanten aufweisen Zu...

Page 7: ...egermeister zu Rate ziehen Dunstabzugshaube niemals an einen Bel ftungsschacht bzw Raum oder Abgaskamin anschlie en Die abge f hrte Luft darf nicht in einen Kanal gef hrt werden in dem Warmluft zir ku...

Page 8: ...uss je nach Benutzung erneuert werden mindestens etwa alle sechs Mo nate berpr fen Abluftbetrieb Beim Abluftbetrieb werden die K chend nste angesaugt ber den Fettfilter gereinigt und ber den Abluftsch...

Page 9: ...Abluftbetrieb WARNUNG Erstickungs Explosionsgefahr Dunstabzugshaube niemals an einen Bel ftungsschacht bzw Raum oder Abgaskamin anschlie en Die abge f hrte Luft darf nicht in einen Kanal gef hrt werde...

Page 10: ...it Ihrer De cken und W nde geeignet ist Sollten Sie sich bei der Auswahl nicht sicher sein lassen Sie sich durch einen Fach mann beraten Werkzeuge und Hilfsmittel Sie ben tigen Schraubendreher Bohrmas...

Page 11: ...tritt von au en mit einer Abde ckung mit selbst ffnenden Schlitzen nicht im Lieferumfang enthalten versehen werden Beauftragen Sie damit einen Fachbetrieb der den Wanddurchbruch vornimmt Bevor Sie die...

Page 12: ...exakt ber der Mitte des Herds zu platzieren zun chst eine Hilfs linie an die Wand zeichnen senkrechte Linie mit Hilfe einer Wasserwaage oder einem Lot von der Mitte des Herds bis zur Decke 2 Dunstabzu...

Page 13: ...Wand montiert 11 Nur bei Abluftbetrieb Die R ckschlag klappe 3 oben auf die Dunstabzugshau be 1 setzen und mit vier Blechschrau ben 4 festschrauben Dieser Arbeitsschritt entf llt wenn das Ger t im Uml...

Page 14: ...bdeckung der Dunstabzugshaube ffnet sich 8 20 Die Verriegelung der Fettfilter 8 zur Seite schieben und beide Fettfilter vor sichtig nach oben abnehmen 21 Alle Schutzfolien von beiden Fettfiltern abzie...

Page 15: ...ziehen oder Strom an der entsprechenden Hauptsicherung abschalten 8 3 Die Verriegelung der Fettfilter 8 zur Seite schieben und Fettfilter vorsichtig nach oben abnehmen 5 4 Die Kohlefilter 5 wie darge...

Page 16: ...aus und Klappe 14 schlie t sich Gebl se Das Gebl se Ihrer Dunstabzugshaube ist in vier Stufen einstellbar Auf der niedrigsten Stufe leuchten 2 der Balken bei der n chst h heren Stufe 4 Balken dann 6 u...

Page 17: ...ltet sein 11 9 1 Bei laufendem Gebl se Taste 9 ber hren Taste 9 sowie die ersten beiden Bal ken der Gebl sest rke Anzeige beginnen zu blinken 2 Um die Abschaltverz gerung anzupas sen w hrend des Betri...

Page 18: ...ulver da diese die Ober chen zerkratzen k nnen Wir empfehlen die Oberfl chen der Dunstab zugshaube nach jeder Benutzung zu reinigen Wischen Sie die Oberfl chen mit einem weichen feuchten Tuch und etwa...

Page 19: ...tzen Die Aktivkohlefilter werden im Umluftbetrieb ben tigt Sie dienen der Geruchsbeseitigung Sie m ssen erneuert werden wenn die beim Kochen entstehenden Ger che nicht mehr ausreichend gefiltert werde...

Page 20: ...stet ein 7 Stromversorgung wieder herstellen 8 Klappe 14 der Dunstabzugshaube durch Ber hren der Taste 13 3 Sekunden lang schlie en Beleuchtung WARNUNG Stromschlaggefahr Das Ber hren von unter Spannun...

Page 21: ...fen Sie die Steckdose mit einem anderen elektrischen Ger t Pr fen Sie die Sicherung Beleuchtung funktioniert nicht LED Lampe defekt Wenden Sie sich an unseren Service siehe Seite 22 l tropft vom Ger...

Page 22: ...den Umluftbe trieb erforderlich und geh rt nicht zum Liefer umfang Sie k nnen ihn unter folgender Artikelnum mernummer beziehen Artikelnummer 625 444 Damit wir Ihnen schnell helfen k nnen nennen Sie u...

Page 23: ...Aktivkohlefilter entsorgen Die verbrauchten Aktivkohlefilter k nnen Sie mit dem Hausm ll entsorgen Verpackung Unsere Verpackungen werden aus umweltfreundlichen wiederverwert baren Materialien hergest...

Page 24: ...User manual Manual version 196635_20180724_UK EN Article no 53906622 Reproduction even of ex cerpts is not permitted SY 103D1 E3 C25 900 Underframe exhaust hood...

Page 25: ...nd off 16 Fan 16 Timer switch off delay 17 Control light 17 Care and maintenance 18 Cleaning the housing 18 Cleaning the grease filters 18 Inserting replacing activated charcoal filters 19 Lighting 20...

Page 26: ...s and dowels required to mount the appliance on a wall as their type and dimensions will vary depending on the characteristics of the wall Please have a specialist advise you as to which ones you need...

Page 27: ...ful addi tional information Explanation of symbols Broken glass Protection class I Safety notices In this chapter you will nd general safety notices which you must always observe for your own protecti...

Page 28: ...dependent or improper repairs made to the appliance may cause damage to property and personal in jury any liability and warranty claims will be forfeited Never try to repair a defective or suspected d...

Page 29: ...nt Only use mounting materials that are suitable for the characteristics of the ceiling and walls When in doubt con sult an expert Fire hazard The distance between the cooking surfaces and the lower e...

Page 30: ...on sys tem throughout the home must be reviewed Consult the gas safety con sultant who is responsible for the home Never attach the exhaust hood to a ventilation shaft chimney or smoke stack The air b...

Page 31: ...ffec tivity of the filter and exhaust functions The activated charcoal filter must be replaced depending on use check it at least every six months Exhaust air operation When air is extracted the cooki...

Page 32: ...allation For exhaust air operation WARNING Risk of suffocation explosion Never attach the exhaust hood to a ventilation shaft chimney or smoke stack The air being extracted must not travel through a c...

Page 33: ...suitable for the characteristics of the ceiling and walls If you are not sure of your selection ask a professional for guidance Tools and aids You will need Screwdriver Drill with stonebit 8 mm Measur...

Page 34: ...e outside must have a cover with self opening slits not included in the package contents Hire a spe cialist to carry out the wall break Before installing the exhaust hood the wall break core drilling...

Page 35: ...the ceiling 2 Hold the exhaust hood 1 up to the wall in such a way that the distance from the cooker for gas cookers at least 65 cm is correct and the middle of the exhaust hood is flush to the vertic...

Page 36: ...circulation air operation 12 If the exhaust hood is being installed be neath a cupboard mark the air outlet for the exhaust air hose 2 on the bottom of the cabinet and saw the opening into the cabine...

Page 37: ...haust hood the appliance is ready touse Inserting activated charcoal filter for circulation air operation A carbon filter odour filter is filled with acti vated carbon which reduces kitchen fumes duri...

Page 38: ...wise allowing the locks to click into place 8 5 Insert the grease filter 8 by placing the back end in the recess on the exhaust hood Slide the lock backwards hinge the grease filter 8 downwards to clo...

Page 39: ...ngs At the lowest setting 2 of the bars will be illu minated 4 bars on the next highest setting then 6 and at the highest setting 8 Always switch the fan on as soon as you start cooking or frying This...

Page 40: ...an display will begin to flash 2 In order to adapt the switch off delay touch the button 9 in the area which approximately corresponds to the re quired switch off delay The correspond ing number of ba...

Page 41: ...rp objects or scour ing powders as these can scratch the surface We recommend cleaning the surfaces of the exhaust hood after every use Wipe the surfaces with a soft damp cloth and a little dishwashin...

Page 42: ...ng replacing activated charcoal filters Activated charcoal filters are required for circulation air operation They help combat odours They have to be replaced as soon as the cooking odours can no long...

Page 43: ...the recess Slide the lock upwards press down on the grease filter and re lease the lock The grease filter engages 7 Reconnect the power supply 8 Close the exhaust hood s cover 14 by pressing the butto...

Page 44: ...rrectly Check the socket by con necting another electric device Check the fuse Lighting not working LED bulb is defective Contact our service team for this see page 22 Grease is dripping off the appli...

Page 45: ...filters An activated charcoal filter is only required for air circulation and is not included in the package contents You can order it under the following article number Article number 625 444 In ord...

Page 46: ...irectly for more information about this topic Disposing of activated charcoal filters You can dispose of activated charcoal filters with your household waste Packaging Our packaging is made from envi...

Page 47: ...ion PS 0 34 Time delay factor f 1 4 Energy efficiency index EEI hood 84 1 Optimal metered air volume flow in m3 h QBEP 354 6 Optimal metered air pressure in Pa PBEP 293 Optimal metered electrical inpu...

Page 48: ...ftszustand PS 0 34 Zeitverl ngerungsfaktor f 1 4 Energieeffizienzindex EEIhood 84 1 Gemessener Luftvolumenstrom im Bestpunkt in m3 h QBEP 354 6 Gemessener Luftdruck im Bestpunkt in Pa PBEP 293 Gemesse...

Reviews: