13.  ACCESSORIES

Ordering Information

Product Description

DO Solutions

HI7040L

Zero oxygen solution set, 500 mL + 12 g

Other Accessories

HI60501

PVC immersion electrode holder

HI60501-0

O-rings for 

HI60501

 electrode holder

HI60501-2

PVC protective end cap, inside height 68 mm (2.6”)

HI605011

PVC mounting flange

HI764113-1

DO Smart Cap with O-ring

HI764113-2

Calibration /Storage vessel for 

HI764113

 optical DO probe

HI76510-05

Patch cable, 5 m (16’5”)

HI76510-10

Patch cable, 10 m (32’9”)

HI76510-15

Patch cable, 15 m (49’2”)

HI76510-25

Patch cable, 25 m (82’)

HI76510-50

Patch cable, 50 m (164’)

BL120-400

Flow-cell probe adapter kit

BL120-401

Flow-cell valve

BL120-402

Flow-cell tubing,10 m (32’9”)

BL120-410

Flow cell

BL120-450

Flow-cell kit for Ø 50 mm (2”) pipe

BL120-463

Flow-cell kit for Ø 63 mm (2.5”) pipe

BL120-475

Flow-cell kit for Ø 75 mm (3”) pipe

BL120-500

Probe fitting kit

For additional accessories information contact your local sales office.

14.  ABBREVIATIONS

ABS

  Acrylonitrile Butadiene Styrene

HDPE

  High Density Polyethylene

NBR

  Nitrile Butadiene Rubber

NPT

  American National Pipe Standard Taper Pipe Thread

PMMA

  Polymethyl Methacrylate

PVDF

  Polyvinylidene Fluoride

Summary of Contents for HI7640-58

Page 1: ...nload the HI510 controller user manual https manuals hannainst com HI510 Hanna is committed to developing and deploying digital solutions with a positive impact on the environment and climate 0 to 50...

Page 2: ...essories 14 14 Abbreviations 14 Certification 15 Recommendations for Users 15 Warranty 15 Dear Customer Thank you for choosing a Hanna Instruments product Please read this instruction manual carefully...

Page 3: ...are all accessible inside controller s enclosure Before powering the controller verify the probe wiring has been done following the instructions detailed in this manual 3 GENERAL DESCRIPTION INTENDED...

Page 4: ...ed oxygen Over time the sensor s optical components can age but are compensated for by using the reference signal to compensate the measuring path As a result the sensor provides accurate dissolved ox...

Page 5: ...red by the user in saturation or mg L Temperature Range 5 0 to 50 0 C 23 0 to 122 0 F Resolution 0 1 C 0 1 F Accuracy 0 3 C 0 5 F Calibration Single point offset controller setting Temperature compens...

Page 6: ...Remove the protective cap 3 Locate the O ring that sits on probe body Sparingly lubricate with a thin film of supplied grease Use care to prevent grease fingerprints from contacting the optical window...

Page 7: ...stalled using the 3 4 NPT external threads Hand tighten the probe in position Then depending on the process tighten one or two turns with a wrench to secure in place Do not exceed 10 N m 7 3 lb ft tor...

Page 8: ...shing 5 attached to the probe E The upper portion of the pipe should be sealed step II to prevent ingress of water if installed outdoor F Attach the pipe to a handrail Low thread immersion installatio...

Page 9: ...temperature differences greater than 2 C 36 F between tank content and flow cell sample Shade the assembly from direct sunlight TANK VALVE 1 VALVE 2 FLOW FLOW INCOMING FLOW EXIT FLOW 3 1 2 4 5 7 6 6...

Page 10: ...de Marking Attached cable Patch cable Functionality GREEN BLACK 0V B WHITE WHITE RS485 D A YELLOW BLUE RS485 D BROWN RED 5V g GREEN YELLOW Protective ground connection See Accessories section for cabl...

Page 11: ...8 26 mg L suspend the probe in water saturated air This condition corresponds to 100 air saturated water at the temperature of measurement 1 Use of calibration beaker containing some water or moisten...

Page 12: ...lope if values are over 20 12 MAINTENANCE General Maintenance Inspect O ring for nicks or other damage Replacing the o ring is advised Do not substitute other grease or lubricants as it may cause the...

Page 13: ...e the new O ring from the container and slide on the probe tip do not roll or twist the O ring 8 Use a syringe filled with silicone grease and sparingly lubricate the O ring with a thin film of grease...

Page 14: ...10 m 32 9 HI76510 15 Patch cable 15 m 49 2 HI76510 25 Patch cable 25 m 82 HI76510 50 Patch cable 50 m 164 BL120 400 Flow cell probe adapter kit BL120 401 Flow cell valve BL120 402 Flow cell tubing 10...

Page 15: ...dous environments WARRANTY The probes are warrantied for two years against defects in workmanship and materials when used for its intended purpose and maintained according to instructions HI764113 1 S...

Page 16: ......

Reviews: