HS / HL Valves & Systems Service Manual
Hankscraft Runxin, LLC 300 Wengel Drive 608.524.9465 hrh2o.com [email protected]
53
8.
Remove and inspect impeller for gear or spindle damage, replace if necessary.
9.
Apply silicone lubricant to new O-ring and assemble to the smallest diameter on meter cover.
10.
Assemble cover to meter module. Be sure impeller spindle enters freely into cover. Press firmly
on cover and rotate if necessary to assist in assembly.
11.
Replace four screws and tighten.
12.
Return bypass to normal In Service position. Water pressure automatically builds in the system.
Be sure to shut off any bypass line.
13.
Check for leaks at all seal areas.
14.
Plug electrical cord into outlet.
15.
Set time of day.
16.
Return the control valve to the In Service position.
17.
Rotate program wheel counterclockwise until it stops at Regeneration position.
18.
Start regeneration cycle manually if water is hard.
19.
Plug cable into meter cover. Rotate cable to align drive flat if necessary.