HS / HL Valves & Systems Service Manual
Hankscraft Runxin, LLC 300 Wengel Drive 608.524.9465 hrh2o.com [email protected]
46
e.
Apply silicone lubricant to new O-Ring and install around oval extension on injector cap.
10.
Apply silicone lubricant to three new O-Rings and install over three bosses on injector body.
11.
Insert screws with washers through injector cap and injector.
12.
Place this assembly through hole in timer housing and into mating holes in the valve body.
Tighten screws.
13.
Reconnect brine tube and drain line.
14.
Return bypass to In Service position. Water pressure automatically builds in the system.
Be sure to shut off any bypass line.
15.
Check for leaks at all seal areas.
16.
Check drain seal with the valve in the Backwash position.
17.
Plug electrical cord into outlet.
18.
Set time of day.
19.
Return the control valve to the In Service position.
Make sure there is enough brine in the brine tank.
20.
Rotate program wheel counterclockwise until it stops at regeneration position.
21.
Start regeneration cycle manually if water is hard.
Replacing Timer
1.
Unplug electrical cord from outlet.
2.
Turn off water supply to system.