HS / HL Valves & Systems Service Manual
Hankscraft Runxin, LLC 300 Wengel Drive 608.524.9465 hrh2o.com [email protected]
10
Bypass Installation
Stainless Steel Bypass – 1606K/1606KB
1.
Grease bypass O-rings and press onto valve.
2.
Secure with clips.
Before running the valve for the first time,
flush out the water line and bypass:
3.
Be sure the bypass is closed.
4.
Turn the water source on at the inlet to the house.
5.
Disconnect the bypass from the valve.
6.
Put a container under the bypass. Open the bypass to remove any foreign material out of the
water lines.
7.
Close the bypass.
8.
Re-connect the bypass to the valve.
9.
Open the bypass slowly, to avoid water hammering.
10.
Let water flow into the pressure tank. When water flow stops, slowly open a cold water tap
nearby and let water run until it runs clear and air is purged from the unit. Then close tap.
11.
Check for and repair any leaks.
12.
Start-up procedures are shown on the following pages for each different valve type. Locate your
valve type and follow the start-up procedures listed.