34
P&ID Schematic
Models 500 through 600 (Contact factory to request certified drawings)
10
WET GAS
INLET
2
1
17
5
19
21
29
19
16
42
43
13
6
23
24
20
DRY GAS
OUTLET
25
28
27
4
54
SOL 'D'
V1
SOL 'F'
EXH.
V9
RTD 1
V3
V4
V2
SOL 'B'
EXH.
SOL 'A'
SOL 'G'
V10
RTD 2
V6
1PS
(RTD4/HS1)
ENERGY MGMT OPTION
SET @ 176°F
DRYING
EXH.
3PS
SET @
5 PSIG
SOL 'C'
2
1
3
LEFT
TOWER
SET @
45 PSIG
M
RTD 3
SET @ 650°F
1TC
SET @ 370°F
V5
2PS
SET @ 176°F
4PS
SET @
5 PSIG
18
REGEN
9
SET @
45 PSIG
SET AT
100 PSIG
RIGHT
TOWER
12
11
8
7
V8
26
V12
V13
SOL 'E'
V7
V11
SET @ 165 PSIG
DEWPOINTER OPTION
DPA
15
3
22
14
13
44A
SOLENOID VALVES 'B'� 'D'� � 'G' ARE SHOWN ENERGI�ED �
SYMBOLS ARE PER ANSI Y32.10 �GRAPHIC SYMBOLS FOR FLUID POWER DIAGRAMS.�
SOLENOID VALVES 'A'� 'C'� 'E'� � 'F' ARE SHOWN DE�ENERGI�ED .
AS SHOWN FLOW DIRECTION IS�
INDICATES OPTION
3.
2.
1.
PILOT GAS LINE
RIGHT CHAMBER REGEN
LEFT CHAMBER DRYING
NOTES
4.
44
Summary of Contents for HBP Series