3.4 Risk of electrical shock
This machine is not insulated and has no electric shock protection.
All operators and managers should follow the relevant national or local regulations
on the minimum safety distance of live conductors above ground. If there are no
such requirements, the operators and managers should follow the requirements on
the minimum safety distance listed in the table.
Min. safe distance of live conductors
Voltage Range
(Phase
-
Phase, kV)
Min. Safe
Distance
M (ft)
0
-
50
3 (10)
50
-
200
5 (15)
200
-
350
6 (20)
350
-
500
8 (25)
500
-
750
11 (35)
750
-
1,000
14 (45)
3.5 Danger of rollover
Max. load capacity of the platform
Model
Max Load
Max Load Capacity
Max Number of
Max Manual Operating
Risk of electrical shock.
★
Follow the relevant government rules and always keep a safe distance from power cables and
electrical equipment, as shown in the following table.
★
Take the platform movement and wire swinging or sagging into account, take care in strong or
gusty winds, and do not operate the machine in lightning or heavy rain.
★
Stay away from the machine if the machine contacts live wires. Before the power is cut off,
personnel on the ground or platform are must not touch or operate the machine.
★
Do not use the machine as a ground wire during welding and polishing operations.