67
6. After the BMS is charged, the charging termination command is sent, and the charger ends
the charging.
7. During the charging process, the charger is faulty (the "overheat" and "abnormal" lights of
the charger information are all charger faults), the BMS is fully charged or the "charging permission"
is in the prohibited state, and the charging control is artificially in the "stop" state will terminate
charging.
User wiring instructions
The AC input air switch switches the power supply of the whole machine. The input is the Yida plug,
and the output is the charging gun
Warning: PE protection earth must be connected, otherwise it may threaten the safety of life.
Instructions
1. Precautions
a. Before the charger is turned on, it should be checked whether the battery box wiring is
correct, whether there will be a short circuit or a positive and negative electrode connection. In
order to avoid overloading the charger to burn components or lines.
b. It can be put into use only after the charger has no abnormal, overheating and other warning
information.
c. For the safety of charging machines and equipment, it is forbidden to directly disconnect the
battery switch under the condition of output current, except in case of emergency.