5 - 6
Quick Check® SV Series User’s Guide
6. A few iterations of commands will probably be needed, therefore it will be
necessary to access the Transmit SV Commands Screen and Reflectance
Profile Mode alternately.
Note: A short cut to the Reflectance Profile Mode is accessed by pressing F3.
7. Like most other SV commands – new scanner settings are enabled
immediately when received, but to be stored to non-volatile memory so they
are maintained on a power up condition, the ~Hx command must be
transmitted after the desired settings are achieved.
Desired Signal Amplitude and Placement
• Bar code signal amplitude
at least 6 lines high. (A
more preferred 7 lines
high is shown in this
example.)
• Bar code signal
placement within the