6 - 14
Quick Check® SV Series User’s Guide
This command instructs the verifier on how many bar codes it is expected to read
and analyze during a sync period. If the programmed number of codes are not
read, a (robust) NO READ condition is internally flagged for communications or
output port activation. Except for mode ~LV03, this command sets the minimum
bar codes expected. Mode ~LV03 uses this value for the EXACT number of
codes read during the sync interval.
Note: See ~LZ## command (
page 6-16
) for other options.
## = 01 through 99
Default = 01.
~LP#
Set Sync Polarity (See
"Sync Inputs" on page 2-2
for examples of sync input polar-
ities.)
# =
~LQ#
Enable or Disable Port Activations by Partial Decodes
~LR#
Enable or Disable No Read Transmission
A No Read transmission message can be sent via the serial port if the SV unit is
receiving sync inputs. See
"Serial Port Transmission Format" on page 3-1
for
details. Fields y, M and N (data positions 52 through 55) set to 0, indicate a No
Read condition.
Values for # are:
0
Falling edge of signal is active
1
Rising edge of signal is active
0
Disable Port Activation by Partial Decodes
1
Enable Port Activation by Partial Decodes
1
enables the No Read message to be transmitted
0
disables the No Read transmission
Summary of Contents for SV series
Page 1: ... User s Guide Quick Check SV Series Bar Code Scanner Verifier ...
Page 8: ...iv ...
Page 16: ...2 6 Quick Check SV Series User s Guide ...
Page 22: ...3 6 Quick Check SV Series User s Guide ...
Page 98: ...8 6 Quick Check SV Series User s Guide ...
Page 103: ......